Literature DB >> 22672765

A moving-part-free protamine-sensitive polymeric membrane electrode for sensitive biomedical analyses.

Xuewei Wang1, Qing Wang, Wei Qin.   

Abstract

Traditional potentiometric polyion-sensitive electrodes can only work effectively in samples with vigorous convection fulfilled by magnetic stirrer, electrode rotator, or other moving components. The dependence on complex moving parts prohibits the fabrication of compact, cost-effective, and energy-effective test devices from the commercial point of view. In this paper, a novel potentiometric sensing protocol without using any moving parts has been proposed for polycationic protamine. In contrast to traditional protamine-sensitive electrodes conditioned by discriminated ion (Na(+)), the proposed electrode is conditioned with primary ion (protamine). Upon a medium exchange from the conditioning solution into an unstirred sample solution without protamine, protamine loaded in the membrane is stripped into the aqueous phase via ion exchange with aqueous sodium ion, thereby inducing a large potential drop. Interestingly, when the sample solution initially contains protamine, the ion-exchange process has been found to be sensitively inhibited by the sample protamine, and thus the potential drop is suppressed, which forms the basis of the moving-part-free potentiometric polyion sensing strategy. Utilizing the digestion ability of protease to protamine, the electrode was employed to determine the activity of trypsin with a detection limit at least one order of magnitude lower than traditional potentiometric methods. The trypsin inhibitor in both buffer and plasma samples was also sensitively detected with the moving-part-free protamine-sensitive electrode. Finally, the ability of the proposed electrode to detect polyanionic heparin was demonstrated.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22672765     DOI: 10.1016/j.bios.2012.05.020

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  1 in total

1.  Detecting Levels of Polyquaternium-10 (PQ-10) via Potentiometric Titration with Dextran Sulphate and Monitoring the Equivalence Point with a Polymeric Membrane-Based Polyion Sensor.

Authors:  Stephen A Ferguson; Xuewei Wang; Mark E Meyerhoff
Journal:  Anal Methods       Date:  2016-07-04       Impact factor: 2.896

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.