Literature DB >> 22672219

Softness sensor system for simultaneously measuring the mechanical properties of superficial skin layer and whole skin.

Masashi Nakatani1, Toru Fukuda, Naomi Arakawa, Tomoyuki Kawasoe, Sadao Omata.   

Abstract

BACKGROUND/AIMS: Few attempts have been made to distinguish the softness of different skin layers, though specific measurement of the superficial layer would be useful for evaluating the emollient effect of cosmetics and for diagnosis of skin diseases.
MATERIALS AND METHODS: We developed a sensor probe consisting of a piezoelectric tactile sensor and a load cell. To evaluate it, we firstly measured silicone rubber samples with different softness. Then, it was applied to human forearm skin before and after tape-stripping. A VapoMeter and skin-surface hygrometer were used to confirm removal of the stratum corneum. A Cutometer was used to obtain conventional softness data for comparison. RESULTS AND
CONCLUSIONS: Both the piezoelectric tactile sensor and the load cell could measure the softness of silicone rubber samples, but the piezoelectric tactile sensor was more sensitive than the load cell when the reaction force of the measured sample was under 100 mN in response to a 2-mm indentation. For human skin in vivo, transepidermal water loss and skin conductance were significantly changed after tape-stripping, confirming removal of the stratum corneum. The piezoelectric tactile sensor detected a significant change after tape-stripping, whereas the load cell did not. Thus, the piezoelectric tactile sensor can detect changes of mechanical properties at the skin surface. The load cell data were in agreement with Cutometer measurements, which showed no change in representative skin elasticity parameters after tape-stripping. These results indicate that our sensor can simultaneously measure the mechanical properties of the superficial skin layer and whole skin.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22672219     DOI: 10.1111/j.1600-0846.2012.00648.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  4 in total

1.  A bioinspired stretchable membrane-based compliance sensor.

Authors:  Levent Beker; Naoji Matsuhisa; Insang You; Sarah Rachel Arussy Ruth; Simiao Niu; Amir Foudeh; Jeffrey B-H Tok; Xiaodong Chen; Zhenan Bao
Journal:  Proc Natl Acad Sci U S A       Date:  2020-05-08       Impact factor: 11.205

2.  Blood vessels sense dermal stiffness via a novel mechanotransducer, APJ.

Authors:  Mika Sawane; Yuki Ogura; Ayano Nakamura; Hitomi Otaka; Hiroyasu Kidoya; Katsujiro Sato; Nobuyuki Takakura; Kentaro Kajiya
Journal:  Angiogenesis       Date:  2021-10-06       Impact factor: 9.596

3.  In vivo evaluation of the skin tensile strength by the suction method: pilot study coping with hysteresis and creep extension.

Authors:  Gérald E Piérard; Sébastien Piérard; Philippe Delvenne; Claudine Piérard-Franchimont
Journal:  ISRN Dermatol       Date:  2013-08-05

4.  A Portable Stiffness Measurement System.

Authors:  Onejae Sul; Eunsuk Choi; Seung-Beck Lee
Journal:  Sensors (Basel)       Date:  2017-11-21       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.