Literature DB >> 22669465

Personal glucose sensor for point-of-care early cancer diagnosis.

Jiao Su1, Jin Xu, Ying Chen, Yun Xiang, Ruo Yuan, Yaqin Chai.   

Abstract

Early POC diagnosis of cancer is demonstrated by using multi-invertase conjugated microsphere labels and a personal glucose sensor (PGS) transducer. The invertase, which catalyzes the hydrolysis of sucrose to glucose, enables the PGS to detect target analytes beyond glucose, and the numerous invertase labels involved in each antibody-antigen binding event lead to significantly amplified PGS readings for sensitive protein detection.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22669465     DOI: 10.1039/c2cc32729e

Source DB:  PubMed          Journal:  Chem Commun (Camb)        ISSN: 1359-7345            Impact factor:   6.222


  9 in total

1.  Detection of protein biomarker using a blood glucose meter.

Authors:  Tian Lan; Yu Xiang; Yi Lu
Journal:  Methods Mol Biol       Date:  2015

2.  Dose-Dependent Response of Personal Glucose Meters to Nicotinamide Coenzymes: Applications to Point-of-Care Diagnostics of Many Non-Glucose Targets in a Single Step.

Authors:  Jingjing Zhang; Yu Xiang; Miao Wang; Ananda Basu; Yi Lu
Journal:  Angew Chem Int Ed Engl       Date:  2015-11-23       Impact factor: 15.336

3.  Translating in vitro diagnostics from centralized laboratories to point-of-care locations using commercially-available handheld meters.

Authors:  JingJing Zhang; Tian Lan; Yi Lu
Journal:  Trends Analyt Chem       Date:  2019-12-23       Impact factor: 12.296

Review 4.  Transforming the blood glucose meter into a general healthcare meter for in vitro diagnostics in mobile health.

Authors:  Tian Lan; Jingjing Zhang; Yi Lu
Journal:  Biotechnol Adv       Date:  2016-03-03       Impact factor: 14.227

5.  Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detection.

Authors:  Zhenzhen Li; Yanmei Xin; Zhonghai Zhang; Hongjun Wu; Peng Wang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

6.  Biosensing of DNA oxidative damage: a model of using glucose meter for non-glucose biomarker detection.

Authors:  Xuena Zhu; Mehenur Sarwar; Qiaoli Yue; Chunying Chen; Chen-Zhong Li
Journal:  Int J Nanomedicine       Date:  2017-02-02

7.  Translating molecular detections into a simple temperature test using a target-responsive smart thermometer.

Authors:  Jingjing Zhang; Hang Xing; Yi Lu
Journal:  Chem Sci       Date:  2018-03-07       Impact factor: 9.825

8.  Identification of the gene for β-fructofuranosidase from Ceratocystis moniliformis CMW 10134 and characterization of the enzyme expressed in Saccharomyces cerevisiae.

Authors:  Niël van Wyk; Kim M Trollope; Emma T Steenkamp; Brenda D Wingfield; Heinrich Volschenk
Journal:  BMC Biotechnol       Date:  2013-11-14       Impact factor: 2.563

9.  Sensitive electrochemical nonenzymatic glucose sensing based on anodized CuO nanowires on three-dimensional porous copper foam.

Authors:  Zhenzhen Li; Yan Chen; Yanmei Xin; Zhonghai Zhang
Journal:  Sci Rep       Date:  2015-11-02       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.