A high-throughput comparative characterization of laser-induced soft tissue damage using 3D digital microscopy.

Debobrato Das1, Stephanie Reed, Perry R Klokkevold, Benjamin M Wu.   

Abstract

3D digital microscopy was used to develop a rapid alternative approach to quantify the effects of specific laser parameters on soft tissue ablation and charring in vitro without the use of conventional tissue processing techniques. Two diode lasers operating at 810 and 980 nm wavelengths were used to ablate three tissue types (bovine liver, turkey breast, and bovine muscle) at varying laser power (0.3, 1.0, and 2.0 W) and velocities (1-50 mm/s). Spectrophotometric analyses were performed on each tissue to determine tissue-specific absorption coefficients and were considered in creating wavelength-dependent energy attenuation models to evaluate minimum heat of tissue ablations. 3D surface contour profiles characterizing tissue damage revealed that ablation depth and tissue charring increased with laser power and decreased with lateral velocity independent of wavelength and tissue type. While bovine liver ablation and charring were statistically higher at 810 than 980 nm (p < 0.05), turkey breast and bovine muscle ablated and charred more at 980 than 810 nm (p < 0.05). Spectrophotometric analysis revealed that bovine liver tissue had a greater tissue-specific absorption coefficient at 810 than 980 nm, while turkey breast and bovine muscle had a larger absorption coefficient at 980 nm (p < 0.05). This rapid 3D microscopic analysis of robot-driven laser ablation yielded highly reproducible data that supported well-defined trends related to laser-tissue interactions and enabled high throughput characterization of many laser-tissue permutations. Since 3D microscopy quantifies entire lesions without altering the tissue specimens, conventional and immunohistologic techniques can be used, if desired, to further interrogate specific sections of the digitized lesions.

Entities:  

Mesh:

Year:  2012        PMID: 22669178     DOI: 10.1007/s10103-012-1126-z

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  24 in total

1.  Effects on oral soft tissue produced by a diode laser in vitro.

Authors:  K Goharkhay; A Moritz; P Wilder-Smith; U Schoop; W Kluger; S Jakolitsch; W Sperr
Journal:  Lasers Surg Med       Date:  1999       Impact factor: 4.025

2.  Diode laser (980 nm) in oral and maxillofacial surgical procedures: clinical observations based on clinical applications.

Authors:  G Romanos; G H Nentwig
Journal:  J Clin Laser Med Surg       Date:  1999-10

3.  MR imaging-guided interstitial Nd:YAG laser phototherapy: dosimetry study of acute tissue damage in an in vivo model.

Authors:  Y Anzai; R B Lufkin; D J Castro; K Farahani; B A Jabour; L J Layfield; R Udkoff; W N Hanafee
Journal:  J Magn Reson Imaging       Date:  1991 Sep-Oct       Impact factor: 4.813

4.  Computer-controlled laser ablation: a convenient and versatile tool for micropatterning biofunctional synthetic surfaces for applications in biosensing and tissue engineering.

Authors:  R Vaidya; L M Tender; G Bradley; M J O'Brien; M Cone; G P López
Journal:  Biotechnol Prog       Date:  1998 May-Jun

5.  Pulsed CO2 laser tissue ablation: effect of tissue type and pulse duration on thermal damage.

Authors:  J T Walsh; T J Flotte; R R Anderson; T F Deutsch
Journal:  Lasers Surg Med       Date:  1988       Impact factor: 4.025

6.  Er:YAG laser ablation of tissue: effect of pulse duration and tissue type on thermal damage.

Authors:  J T Walsh; T J Flotte; T F Deutsch
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

7.  Endovenous laser: a new minimally invasive method of treatment for varicose veins--preliminary observations using an 810 nm diode laser.

Authors:  L Navarro; R J Min; C Boné
Journal:  Dermatol Surg       Date:  2001-02       Impact factor: 3.398

8.  Pulsed CO2 laser tissue ablation: measurement of the ablation rate.

Authors:  J T Walsh; T F Deutsch
Journal:  Lasers Surg Med       Date:  1988       Impact factor: 4.025

9.  Comparison of endovenous radiofrequency versus 810 nm diode laser occlusion of large veins in an animal model.

Authors:  Robert A Weiss
Journal:  Dermatol Surg       Date:  2002-01       Impact factor: 3.398

10.  Laser-tissue interaction with a continuous wave 3-mcm fibre laser: preliminary studies with soft tissue.

Authors:  M C Pierce; S D Jackson; M R Dickinson; T A King; P Sloan
Journal:  Lasers Surg Med       Date:  2000       Impact factor: 4.025

View more
  1 in total

1.  Optoacoustic monitoring of cutting efficiency and thermal damage during laser ablation.

Authors:  Erwin Bay; Alexandre Douplik; Daniel Razansky
Journal:  Lasers Med Sci       Date:  2013-10-22       Impact factor: 3.161

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.