| Literature DB >> 22666792 |
José Ailton O Carneiro1, Taiza E G Santos-Pontelli, Karla H C Vilaça, Karina Pfrimer, José F Colafêmina, Antonio Adilton O Carneiro, Eduardo Ferriolli.
Abstract
OBJECTIVE: The aim of this study was to evaluate the multisegmental static postural balance of active eutrophic and obese elderly women using a three-dimensional system under different sensory conditions.Entities:
Mesh:
Year: 2012 PMID: 22666792 PMCID: PMC3351265 DOI: 10.6061/clinics/2012(05)12
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Figure 1The location of the electromagnetic sensors. Tx: transmitter and representation of the three planes. S1 and S2: 1st thoracic vertebra and sacral region.
The physical characteristics of the subjects. The values are reported as the mean ± SD.
| Characteristics | Eutrophic elderly(n = 16) | Obese elderly(n = 15) | |
| Age (years) | 68.3±2.7 | 69.1±2.7 | 0.41 |
| Body height (cm) | 158±0.05 | 153±0.04 | 0.19 |
| Body weight (kg) | 59.1±7.1 | 79.1±8.8 | <0.001 |
| BMI (kg/m2) | 23.4±1.6 | 33.5±3.0 | <0.001 |
| % fat | 35.1±5 | 48.2±4 | <0.001 |
| Lean mass (kg) | 38.1±3.3 | 39.9±3.0 | 0.12 |
| Body fat (kg) | 21.0±5.2 | 37.3±4.9 | <0.001 |
| Waist circumference (cm) | 78.6±5.3 | 97.2±9.4 | <0.001 |
| Hip circumference (cm) | 96.7±6.5 | 111.4±8.3 | <0.001 |
| Hip/waist circ. ratio (cm) | 0.81±0 | 0.87±0.1 | 0.03 |
| Handgrip (kgf) | 25.1±4.6 | 24.8±5.2 | 0.84 |
Abbreviations: BMI, body mass index.
The parameters of postural oscillation recorded by sensor 2 under different conditions.
| Eutrophic Elderly | Obese Elderly | ||
| LOS | mean±SD | mean±SD | |
| Max. displacement (a-p) cm | 32.02±11.92 | 17.35±6.47 | <0.01 |
| Max. displacement (l-l) cm | 23.59±8.01 | 14.49±5.5 | <0.01 |
| Max. displacement (a-p) cm | 2.59±0.1 | 1.95±0.69 | 0.04 |
| Max. displacement (l-l) cm | 1.34±0.64 | 0.98±0.54 | 0.28 |
| Mean speed (a-p) cm/s | 0.96±0.21 | 1.23±0.58 | 0.32 |
| Mean speed (l-l) cm/s | 0.54±0.19 | 0.52±0.25 | 0.32 |
| Max. displacement (a-p) cm | 2.84±1.27 | 1.83±0.50 | <0.01 |
| Max. displacement (l-l) cm | 1.42±1.08 | 1.04±0.59 | 0.38 |
| Mean speed (a-p) cm/s | 1.10±0.35 | 1.24±0.57 | 0.78 |
| Mean speed (l-l) cm/s | 0.57±0.16 | 0.55±0.33 | 0.12 |
| Max. displacement (a-p) cm | 4.24±1.59 | 2.36±0.63 | <0.01 |
| Max. displacement (l-l) cm | 2.45±0.96 | 1.60±0.94 | 0.03 |
| Mean speed (a-p) cm/s | 1.17±0.24 | 1.43±0.63 | 0.51 |
| Mean speed (l-l) cm/s | 0.71±0.16 | 0.66±0.37 | 0.08 |
| Max. displacement (a-p) cm | 4.88±1.90 | 2.59±0.68 | <0.01 |
| Max. displacement (l-l) cm | 3.05±1.34 | 1.69±0.71 | <0.01 |
| Mean speed (a-p) cm/s | 1.26±0.26 | 1.42±0.51 | 0.90 |
| Mean speed (l-l) cm/s | 0.74±0.25 | 0.66±0.27 | 0.14 |
EOSS, eyes open, stable surface; ECSS, eyes closed, stable surface; EOUS, eyes open, unstable surface; ECUS, eyes closed, unstable surface; a-p, anteroposterior axis; l-l, laterolateral axis; Max., maximum.
Figure 2The correlation between maximum a-p displacement and body fat under the different sensory conditions.
Figure 3The representative limit of stability of a eutrophic and an obese elderly woman (registered by sensor 2).
The cross-correlations of S1 and S2 under the different sensory conditions and a comparison of the cross-correlations between groups (Mann-Whitney U test).
| Eutrophic Elderlymean±SD | Obese Elderlymean±SD | ||
| EOSS | 0.99±0.06 | 0.99±0.01 | 0.32 |
| ECSS | 0.99±0.06 | 0.99±0.20 | 0.55 |
| EOUS | 0.99±0.01 | 0.99±0.00 | 0.50 |
| ECUS | 0.99±0.01 | 0.99±0.00 | 0.30 |
EOSS, eyes open, stable surface; ECSS, eyes closed, stable surface; EOUS, eyes open, unstable surface; ECUS, eyes closed, unstable surface; SD, standard deviation.