BACKGROUND: Cardiac resynchronization therapy (CRT) is effective in reducing morbidity and mortality in systolic heart failure patients with cardiac dyssynchrony as demonstrated in studies with primarily Western populations. Although CRT devices with a defibrillator (CRT-D) became available in Japan since 2006, their efficacy remains uncertain in Japanese patients. In this prospective, multicenter study, the efficacy of CRT-D therapy in an all-Japanese population was compared with the study conducted in the US, Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE-ICD). METHODS AND
RESULTS: Ninety-three patients were evaluated according to the subject selection criteria of the MIRACLE-ICD study, and 80 patients were enrolled. Results at baseline and 6-month post-CRT-D implantation were compared in terms of composite clinical response (CCR) and other secondary endpoints. Quality of life (QOL) was assessed with a validated Japanese version of the Minnesota Living with Heart Failure questionnaire. CCR was improved in 55 patients (68.8%), unchanged in 14 (17.5%), and worsened in 11 patients (13.7%) (MIRACLE-ICD general phase: 62.0%, 13.4% and 24.6%, respectively). Non-inferiority was verified by 1-sided test with 10% equivalence margin. QOL score improved significantly (50.0±26.2 vs. 23.6±20.2, P<0.01).
CONCLUSIONS: The MOMIJI study demonstrated that CRT-D effectiveness as assessed with CCR was non-inferior to the trials conducted outside Japan, thus suggesting that the benefits of CRT-D are similar between Japanese and non-Japanese patients.

Entities:  

Mesh:

Year:  2012        PMID: 22664486     DOI: 10.1253/circj.cj-11-1341

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  4 in total

1.  Efficacy of implantable cardioconverter defibrillator or cardiac resynchronization therapy compared with combined therapy in survival of patients with heart failure: a meta-analysis.

Authors:  Jin-Long Deng; Yin-Xiong Wu; Jie Liu
Journal:  Medicine (Baltimore)       Date:  2015-02       Impact factor: 1.889

2.  Predictive value of Tpeak-Tend interval for ventricular arrhythmia and mortality in heart failure patients with an implantable cardioverter-defibrillator: A cohort study.

Authors:  Cong Xue; Wei Hua; Chi Cai; Li-Gang Ding; Hong-Xia Niu; Xiao-Han Fan; Zhi-Min Liu; Min Gu; Yun-Zi Zhao; Shu Zhang
Journal:  Medicine (Baltimore)       Date:  2019-12       Impact factor: 1.889

Review 3.  Heart failure in East Asia.

Authors:  Yutao Guo; Gregory Y H Lip; Amitava Banerjee
Journal:  Curr Cardiol Rev       Date:  2013-05

4.  Adaptive servo-ventilation therapy using an innovative ventilator for patients with chronic heart failure: a real-world, multicenter, retrospective, observational study (SAVIOR-R).

Authors:  Shin-Ichi Momomura; Yoshihiko Seino; Yasuki Kihara; Hitoshi Adachi; Yoshio Yasumura; Hiroyuki Yokoyama
Journal:  Heart Vessels       Date:  2014-08-08       Impact factor: 2.037

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.