Literature DB >> 22661112

Twisted cardiovascular cages for intravascular axial flow blood pumps to support the Fontan physiology.

Amy L Throckmorton1, Emily A Downs, John A Hazelwood, Jonathan O Monroe, Steven G Chopski.   

Abstract

Failing single ventricle physiology represents an ongoing challenge in mechanical assist device development, requiring pressure augmentation in the cavopulmonary circuit, reduction of systemic venous pressure, and increased cardiac output to achieve hemodynamic stabilization. To meet these requirements, we are developing a percutaneously-placed, axial flow blood pump to support ailing single ventricle physiology in adolescents and adults. We have modified the outer cage of the device to serve as both a protective and functional design component. This study examined the performance of 3 cage geometries with varying directions of filament twist using numerical simulations and hydraulic experiments. All 3 cage and pump models performed in acceptable ranges to support Fontan patients. The cage design employing filaments that are twisted in the opposite direction to the impeller blades and in the direction of the diffuser blades (against-with) demonstrated superior performance by generating a pressure rise range of 5-38 mmHg of flow rates of 0.5-6 l/min at rotational speeds of 5000-7000 rpm. The blood damage indices for all of the cages were found to be well below 2%, and the scalar stress levels were below 200 Pa. This study represents ongoing progress in the development of the impeller and cage assembly. Validation of the results will continue in experiments with blood bag evaluation as well as by particle image velocimetry measurements.

Entities:  

Mesh:

Year:  2012        PMID: 22661112     DOI: 10.5301/ijao.5000105

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  2 in total

1.  A viable therapeutic option: mechanical circulatory support of the failing Fontan physiology.

Authors:  Amy L Throckmorton; Sergio Lopez-Isaza; Emily A Downs; Steven G Chopski; James J Gangemi; William Moskowitz
Journal:  Pediatr Cardiol       Date:  2013-02-15       Impact factor: 1.655

2.  A paired membrane umbrella double-lumen cannula ensures consistent cavopulmonary assistance in a Fontan sheep model.

Authors:  Dongfang Wang; Guodong Gao; Mark Plunkett; Guangfeng Zhao; Stephen Topaz; Cherry Ballard-Croft; Joseph B Zwischenberger
Journal:  J Thorac Cardiovasc Surg       Date:  2014-05-16       Impact factor: 5.209

  2 in total