A new technique for measuring wear in total hip arthroplasty using computed tomography.

Dov Goldvasser1, Marilyn E Noz, G Q Maguire, Henrik Olivecrona, Charles R Bragdon, Henrik Malchau.   

Abstract

Accurately estimating polyethylene wear in 3 dimensions, without the need for additional procedures or equipment, is of significant interest. We investigated the use of a high-resolution clinical computed tomographic (CT) scanner to estimate femoral head displacement relative to the cup as an indirect method of estimating polyethylene wear. A hip phantom was used to simulate the 3-dimensional displacement of a femoral head. The phantom was imaged in a high-resolution CT scanner. The mean difference between the true phantom displacement as positioned by micrometers and the calculated displacement based on the CT images was as follows: for the x-axis, 0 mm (SD, 0.213; SE, 0.058); y-axis, 0.039 mm (SD, 0.035; SE, 0.026); and z-axis, 0.039 mm (SD, 0.051; SE, 0.020).
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22658429     DOI: 10.1016/j.arth.2012.03.053

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty: comparison of measurements using a CT algorithm, a coordinate-measuring machine, and a micrometer.

Authors:  Dov Goldvasser; Viktor J Hansen; Marilyn E Noz; Gerald Q Maguire; Michael P Zeleznik; Henrik Olivecrona; Charles R Bragdon; Lars Weidenhielm; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-04-23       Impact factor: 3.717

2.  Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

Authors:  Cyrus Brodén; Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Olof Sköldenberg
Journal:  Biomed Res Int       Date:  2016-07-10       Impact factor: 3.411

3.  Prosthetic liner wear in total hip replacement: a longitudinal 13-year study with computed tomography.

Authors:  Lars Weidenhielm; Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz
Journal:  Skeletal Radiol       Date:  2018-01-23       Impact factor: 2.199

4.  Implant migration and bone mineral density measured simultaneously by low-dose CT scans: a 2-year study on 17 acetabular revisions with impaction bone grafting.

Authors:  Hampus Stigbrand; Keenan Brown; Henrik Olivecrona; Gösta Ullmark
Journal:  Acta Orthop       Date:  2020-05-26       Impact factor: 3.717

5.  A new automated way to measure polyethylene wear in THA using a high resolution CT scanner: method and analysis.

Authors:  Gerald Q Maguire; Marilyn E Noz; Henrik Olivecrona; Michael P Zeleznik; Lars Weidenhielm
Journal:  ScientificWorldJournal       Date:  2014-01-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.