Literature DB >> 2265485

Extracorporeal immunoadsorption therapy on rats. In vivo depletion of specific antibodies.

R Nilsson1, L Lindgren, P Lilliehorn.   

Abstract

A technique for extracorporeal immunoadsorption of circulating specific antibodies from the plasma of rats is described. Catheterization of rats was performed using the carotid and the jugular blood vessels. The rats were treated non-anaesthetized. Blood was pumped continuously through a hollow-fibre plasma filter at a rate of 1.5 ml/min and plasma was separated and passed through an adsorbent column at a flow of 0.2 ml/min. The treated plasma was mixed with the blood cells before being returned to the rat. The column contained the antigen covalently linked to agarose beads. About three plasma volumes were treated during a period of 3 h and 30 min, which resulted in an antibody depletion of about 90-95%. The antibody levels returned to pre-adsorption levels after 4-5 days, or in some cases even exceeded the titres before treatment.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2265485      PMCID: PMC1535513          DOI: 10.1111/j.1365-2249.1990.tb05468.x

Source DB:  PubMed          Journal:  Clin Exp Immunol        ISSN: 0009-9104            Impact factor:   4.330


  13 in total

1.  Permanent cannulation of aorta and vena cava in rats and ground squirrels.

Authors:  V POPOVIC; P POPOVIC
Journal:  J Appl Physiol       Date:  1960-07       Impact factor: 3.531

2.  Removal of anti-HLA antibodies by extracorporeal immunoadsorption to enable renal transplantation.

Authors:  A Palmer; D Taube; K Welsh; M Bewick; P Gjorstrup; M Thick
Journal:  Lancet       Date:  1989-01-07       Impact factor: 79.321

3.  Extracorporeal immunoadsorption of anti-HLA antibodies: preliminary clinical experience.

Authors:  A Palmer; D Taube; K Welsh; H Brynger; K Delin; P Gjörstrup; J Konar; T Söderström
Journal:  Transplant Proc       Date:  1987-10       Impact factor: 1.066

4.  Goodpasture's syndrome treated with staphylococcal protein A immunoadsorption.

Authors:  P Bygren; C Freiburghaus; T Lindholm; O Simonsen; H Thysell; J Wieslander
Journal:  Lancet       Date:  1985-12-07       Impact factor: 79.321

5.  Effect of extracorporeal IgG removal on IgG kinetics.

Authors:  B Charlton; K Schindhelm; P C Farrell
Journal:  Trans Am Soc Artif Intern Organs       Date:  1983

Review 6.  The maintenance and regulation of the humoral immune response: persisting antigen and the role of follicular antigen-binding dendritic cells as accessory cells.

Authors:  J G Tew; R P Phipps; T E Mandel
Journal:  Immunol Rev       Date:  1980       Impact factor: 12.988

7.  Membrane plasmapheresis technique in rats. Confirmation of antibody rebound.

Authors:  H H Euler; U Krey; O Schröder; H Löffler
Journal:  J Immunol Methods       Date:  1985-11-28       Impact factor: 2.303

8.  The effect of extracorporeal antibody removal on antibody synthesis and catabolism in immunized rabbits.

Authors:  B Charlton; K Schindhelm
Journal:  Clin Exp Immunol       Date:  1985-06       Impact factor: 4.330

9.  Repeated membrane plasma separation with on-line sorbent treatment of plasma in the conscious rat.

Authors:  C J Ryan; C D Pusey; M Aslam; J D Gaylor; R Maini; J M Courtney
Journal:  Artif Organs       Date:  1986-04       Impact factor: 3.094

10.  Induction of immune tolerance in patients with hemophilia and antibodies to factor VIII by combined treatment with intravenous IgG, cyclophosphamide, and factor VIII.

Authors:  I M Nilsson; E Berntorp; O Zettervall
Journal:  N Engl J Med       Date:  1988-04-14       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.