| Literature DB >> 22654626 |
R Gallardo-Caballero1, C J García-Orellana, A García-Manso, H M González-Velasco, M Macías-Macías.
Abstract
The presence of clustered microcalcifications is one of the earliest signs in breast cancer detection. Although there exist many studies broaching this problem, most of them are nonreproducible due to the use of proprietary image datasets. We use a known subset of the currently largest publicly available mammography database, the Digital Database for Screening Mammography (DDSM), to develop a computer-aided detection system that outperforms the current reproducible studies on the same mammogram set. This proposal is mainly based on the use of extracted image features obtained by independent component analysis, but we also study the inclusion of the patient's age as a nonimage feature which requires no human expertise. Our system achieves an average of 2.55 false positives per image at a sensitivity of 81.8% and 4.45 at a sensitivity of 91.8% in diagnosing the BCRP_CALC_1 subset of DDSM.Entities:
Mesh:
Year: 2012 PMID: 22654626 PMCID: PMC3349211 DOI: 10.1100/2012/540457
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Figure 1A mammogram region containing microcalcifications expressed as a linear superposition of some ICA-extracted basis functions.
Figure 2(a) Original DDSM mammogram with the expert radiologist's mark surrounding the microcalcification cluster. (b) Mammogram showing the regions of interest generated by our system. The upper ROI accounts for the true abnormality.
Performance results on the BCRP_CALC_1 subset of the five system configurations that generate the lowest false positives per image and provide a sensitivity higher than 80%.
| Configuration | Analyzer | FPi | Sensitivity (%) |
|---|---|---|---|
| ICA-D013C040 | WTA1 | 2.55 | 81.8 |
| ICA-D013C040 | WTA0 | 3.08 | 83.6 |
| ICA-D015C020+AGE | 402040 | 3.25 | 81.4 |
| ICA-D015C024 | WTA1 | 3.40 | 84.2 |
| ICA-D017C020+AGE | WTA3 | 3.44 | 81.8 |
Performance results on the BCRP_CALC_1 subset of the five system configurations that generate the lowest false positives per image and provide a sensitivity higher than 90%.
| Configuration | Analyzer | FPi | Sensitivity (%) |
|---|---|---|---|
| ICA-D017C020+AGE | WTA1 | 4.45 | 91.8 |
| ICA-D017C020+AGE | WTA0 | 4.85 | 91.3 |
| ICA-D019C020+AGE | WTA1 | 4.97 | 91.5 |
| ICA-D015C010+AGE | WTA3 | 5.40 | 91.9 |
| ICA-D015C010+AGE | WTA2 | 5.58 | 92.0 |
Figure 3Free-response operating characteristic curves for systems with the feature extraction configurations ICA-D13C40 (blue trace) and ICA-D17C20+AGE (green trace).