Literature DB >> 22654352

Esthetic Management of Unilateral Cross Bite with Dento-vestibular Enhancement Prosthetic Appliance.

M Dhanraj1, Padma Ariga, S Anand, Ashish R Jain.   

Abstract

Unilateral crossbite is a commonly encountered condition in clinical practice. The most frequently employed treatment protocol to manage unilateral crossbite is orthodontic correction or orthognathic surgery or combination of both. When the clinical situation less favours both these modalities of management, a transitional prosthetic appliance--dentovestibular enhancement prosthetic appliance- can be effectively used to manage this condition.

Keywords:  Dento vestibular enhancement appliance; Esthetics; Unilateral cross bite

Year:  2011        PMID: 22654352      PMCID: PMC3120953          DOI: 10.1007/s13191-011-0077-6

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  9 in total

1.  Treatment of a unilateral Class II crossbite malocclusion with traumatic loss of a maxillary central incisor and a lateral incisor.

Authors:  Roy Sabri
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-12       Impact factor: 2.650

2.  Maxillofacial prosthetic management of the maxillary resection patient.

Authors:  Steven P Haug
Journal:  Atlas Oral Maxillofac Surg Clin North Am       Date:  2007-03

3.  Managing the maxillary partially edentulous patient with extensive anterior tooth loss and advanced periodontal disease using a removable partial denture: a clinical report.

Authors:  Polly S Ma; James S Brudvik
Journal:  J Prosthet Dent       Date:  2008-10       Impact factor: 3.426

4.  Partial denture planning with special reference to stress distribution.

Authors:  A R FRECHETTE
Journal:  J Prosthet Dent       Date:  1951-11       Impact factor: 3.426

5.  A removable partial denture using an esthetically designed round-rest distal clasp on maxillary anterior abutment teeth: a clinical report.

Authors:  Chi Tran; Eugene LaBarre; Howard M Landesman
Journal:  J Prosthet Dent       Date:  2009-11       Impact factor: 3.426

Review 6.  Alternate framework designs for removable partial dentures.

Authors:  E Budtz-Jorgensen; G Bochet
Journal:  J Prosthet Dent       Date:  1998-07       Impact factor: 3.426

7.  Clasp design for extension-base removable partial dentures.

Authors:  A J Krol
Journal:  J Prosthet Dent       Date:  1973-04       Impact factor: 3.426

8.  New technique for semipermanent replacement of missing incisors.

Authors:  J Artun; B U Zachrisson
Journal:  Am J Orthod       Date:  1984-05

9.  A technique to fabricate a customized interim removable partial denture.

Authors:  Hai Zhang; Rich Lee; Kwok-Hung Chung
Journal:  J Prosthet Dent       Date:  2009-09       Impact factor: 3.426

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.