Literature DB >> 22651838

Access-site complications and their management during transradial cardiac catheterization.

Tariq Bhat1, Sumaya Teli, Hilal Bhat, Muhammad Akhtar, Mustafain Meghani, James Lafferty, Bhavesh Gala.   

Abstract

Transradial access for cardiac catheterization is now widely accepted among the invasive cardiology community as a safe and viable approach with a markedly reduced incidence of major access-related complications compared with the transfemoral approach. As this access technique is now being used more commonly for cardiac catheterization, it is of paramount importance to be aware of its complications and to understand their prevention and management. Some of the common complications of transradial access include asymptomatic radial artery occlusion, nonocclusive radial artery injury and radial artery spasm. Among these complications, radial artery spasm is still a significant challenge. Symptomatic radial arterial occlusion, pseudoaneurysm and radial artery perforation are rarely reported complications of the transradial approach. Early identification of these rare complications and their immediate management is of vital importance. Arteriovenous fistula, minor nerve damage and complex regional pain syndrome are very rare but have been reported. Recently, granulomas have been reported to be associated with the use of a particular brand of hydrophilic sheaths during the procedure. Generally, access-site complications can be minimized by avoiding multiple punctures, selection of smaller sheaths, gentle catheter manipulation, adequate anticoagulation, use of appropriate compression devices and avoiding prolonged high-pressure compression. In addition, careful observation for any ominous signs such as pain, numbness and hematoma formation during and in the immediate postprocedure period is essential in the prevention of catastrophic hand ischemia.

Entities:  

Mesh:

Year:  2012        PMID: 22651838     DOI: 10.1586/erc.12.16

Source DB:  PubMed          Journal:  Expert Rev Cardiovasc Ther        ISSN: 1477-9072


  11 in total

1.  Successful treatment of a radial artery pseudoaneurysm in an octogenarian.

Authors:  Mohamed Osama Mohamed; Mohsin Saif; John N Townend; Sohail Q Khan
Journal:  BMJ Case Rep       Date:  2015-08-04

2.  Iatrogenic radial arteriovenous fistula.

Authors:  Nagaraja Moorthy; Rajiv Ananthakrishna
Journal:  Heart Asia       Date:  2017-09-28

3.  Effectiveness of a Non-Taped Compression Dress in Patients Receiving Cardiac Implantable Electronic Devices.

Authors:  Chih-Yin Chien; Ya-Hui Chang; Yih-Jer Wu; Po-Lin Lin; Wei-Ru Chiou; Bo-Ching Chi; Hsu-Ping Wu; Feng-Ching Liao; Ying-Hsiang Lee
Journal:  Acta Cardiol Sin       Date:  2019-05       Impact factor: 2.672

4.  Revealing the impact of local access-site complications and upper extremity dysfunction post transradial percutaneous coronary procedures.

Authors:  E M Zwaan; A G M M Koopman; C A J Holtzer; F Zijlstra; M J P F Ritt; G Amoroso; E Moerman; M J M Kofflard; A A J IJsselmuiden
Journal:  Neth Heart J       Date:  2015-11       Impact factor: 2.380

5.  Complex Regional Pain Syndrome Type II Secondary to Endovascular Aneurysm Repair.

Authors:  Hamilton Chen; Sharwin Tafazoli
Journal:  Case Rep Vasc Med       Date:  2015-01-11

Review 6.  Complex regional pain syndrome and acute carpal tunnel syndrome following radial artery cannulation: a neurological perspective and review of the literature.

Authors:  Reynaldo P Lazaro
Journal:  Medicine (Baltimore)       Date:  2015-01       Impact factor: 1.889

7.  Successful Nonsurgical Treatment of a Radial Artery Pseudoaneurysm Following Transradial Coronary Angiography.

Authors:  Reza Ghanavati; Mehran Arab Ahmadi; Behdad Behnam
Journal:  J Tehran Heart Cent       Date:  2017-04

8.  Surgery Averted Using a Novel, Minimally Invasive Approach to Treat Very Severe Radial Artery Spasm.

Authors:  Anthony A Cochet; Daniel A Bellin
Journal:  Case Rep Cardiol       Date:  2017-08-02

9.  A prospective randomized comparison of left and right radial approach for percutaneous coronary angiography in Asian populations.

Authors:  Hongyu Hu; Qiang Fu; Wei Chen; Dezhao Wang; Xu Hua; Buxing Chen
Journal:  Clin Interv Aging       Date:  2014-06-20       Impact factor: 4.458

10.  Efficacy and safety of a 260-cm Amplatz Super Stiff guidewire during transradial percutaneous coronary intervention.

Authors:  Xuguang Feng; Xiaoyun Zhang; Jun Dai; Jianping Bin
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.