Literature DB >> 22649920

Immunoreactivity and detection of wheat proteins by commercial ELISA kits.

Girdhari M Sharma1.   

Abstract

Wheat proteins are responsible for sensitivities, including baker's asthma, immunoglobulin E (IgE)-mediated allergic reaction, wheat-dependent, exercise-induced anaphylaxis, and celiac disease. The detection of gluten/wheat traces in foods is important to safeguard the health of wheat-sensitive individuals and comply with food labeling. Many immunoanalytical-based commercial kits are available for the quantification of gliadin/gluten/wheat proteins. We compared the immunoreactivity of wheat fractions with wheat-allergic human serum IgE and antibody conjugates used in six commercial immunoassay kits. Moreover, the performance of the kits was tested using corn flour spiked with gluten (5, 10, 25, and 50 ppm) and wheat flour (50, 100, 250, and 500 ppm). The albumin, globulin, gliadin, and glutenin fractions reacted with IgE from nine, eight, two, and eight patients' sera, respectively, out of nine wheat allergic patients tested. Among the antibodies from commercial kits, those from R-Biopharm, Morinaga, and Romer Labs reacted strongly with the gliadin fraction, whereas those from BioKits, ALLER-TEK, and ELISA Systems reacted strongly with the glutenin fraction. All kits showed minimal or no reactivity with albumin and globulin fractions. All kits detected the gluten and wheat flour in a corn flour matrix at the lowest spiked levels of 5 and 50 ppm, respectively. However, there was wide variation among the kits when comparing the recovery of gluten and wheat flour. The recovery was also dependent on the source material (gluten or wheat flour) used for spiking the corn flour matrix.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22649920     DOI: 10.5740/jaoacint.sge_sharma

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  2 in total

1.  The feasibility of harmonizing gluten ELISA measurements.

Authors:  Malgorzata Rzychon; Marcel Brohée; Fernando Cordeiro; Reka Haraszi; Franz Ulberth; Gavin O'Connor
Journal:  Food Chem       Date:  2017-04-18       Impact factor: 7.514

2.  Quantification of Hordeins by ELISA: the correct standard makes a magnitude of difference.

Authors:  Gregory J Tanner; Malcolm J Blundell; Michelle L Colgrave; Crispin A Howitt
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.