Literature DB >> 22648981

Effect of processing methods for transmission electron microscopy on corneal collagen fibrils diameter and spacing.

Saeed Akhtar1.   

Abstract

INTRODUCTION: The corneal tissue was processed in fixatives and embedded in resin for transmission electron microscopy to observe the ultrastructure of the collagen fibrils (CFs). The effect of these processing methods on the CF diameter and the interfibrillar spacing was studied.
METHODS: Four normal human corneal buttons were used for this study. A part of each cornea was fixed in 2.5% glutaraldehyde containing cuprolinic blue in sodium acetate buffer and embedded in spurr's resin (SpurrCB). A second part of each cornea was fixed in 2.5% glutaraldehyde + osmium tetroxide and embedded spurr's resin (SpurrOsm). The third part of each cornea was fixed in paraformaldehyde (4%) and embedded in LR White at 4°C (LRWhite). Ultrathin sections were stained with uranyl acetate and lead citrate.
RESULTS: In the tissue, fixed in SpurrCB, the diameter was 38.4 ± 5.9 nm and spacing between CF was 52.5 ± 5.3 nm. In the tissue fixed in SpurrOsm, the diameter was 28.37 ± 5.84 nm and spacing between CF was 45 ± 4.57 nm. In the tissue fixed in LR White, the CF diameter was 24 ± 2.3 nm and spacing between CF was 39.0 ± 4.2 nm. The diameters and interfibrillar spacing of the tissue processed by SpurrCB, SpurrOsm, and LRWhite were significantly different (P < 0.001) from one another.
CONCLUSION: Our study shows that there is a variation in the CF diameter and spacing depending on the method of fixation and embedding resins used. This needs to be considered when comparative studies using different methods are done.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22648981     DOI: 10.1002/jemt.22083

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  5 in total

1.  Collagen Fibril Ultrastructure in Mice Lacking Discoidin Domain Receptor 1.

Authors:  Jeffrey R Tonniges; Benjamin Albert; Edward P Calomeni; Shuvro Roy; Joan Lee; Xiaokui Mo; Susan E Cole; Gunjan Agarwal
Journal:  Microsc Microanal       Date:  2016-06       Impact factor: 4.127

2.  Development of a novel in vivo corneal fibrosis model in the dog.

Authors:  K M Gronkiewicz; E A Giuliano; K Kuroki; F Bunyak; A Sharma; L B C Teixeira; C W Hamm; R R Mohan
Journal:  Exp Eye Res       Date:  2015-10-09       Impact factor: 3.467

3.  Keeping an eye on decellularized corneas: a review of methods, characterization and applications.

Authors:  Samantha L Wilson; Laura E Sidney; Siobhán E Dunphy; James B Rose; Andrew Hopkinson
Journal:  J Funct Biomater       Date:  2013-07-10

4.  Pilot study on the effects of preservatives on corneal collagen parameters measured by small angle X-ray scattering analysis.

Authors:  Susyn Joan Kelly; Lizette duPlessis; John Soley; Frazer Noble; Hannah Carolyn Wells; Patrick John Kelly
Journal:  BMC Res Notes       Date:  2021-02-27

5.  A unique pre-endothelial layer at the posterior peripheral cornea: ultrastructural study.

Authors:  Saeed Akhtar; Ramachandran Samivel; Adrian Smedowski; Aljoharah Alkanaan; Ali Masmali; Omar Kirat; Adnan Ali Khan; Turki Almubrad
Journal:  Sci Rep       Date:  2022-02-15       Impact factor: 4.379

  5 in total