Literature DB >> 22648108

Differences in biomechanical stability using various fibrin glue compositions for mesh fixation in endoscopic inguinal hernia repair.

Christine Schug-Pass1, Dietmar A Jacob, Hans Lippert, Ferdinand Köckerling.   

Abstract

BACKGROUND: In hernia surgery, mesh fixation with fibrin glue instead of tacks and sutures can demonstrably reduce postoperative morbidity without increasing recurrence rates. In some cases there are significant differences in the biomechanical properties, depending on the functional structure of the meshes. Furthermore, there are various fibrin glue products on the market and these are used for mesh fixation. This study compared the fixation strength of fibrin glues in combination with various meshes.
METHODS: Three different lightweight polypropylene meshes (TiMESH™ light, ULTRAPRO™, Optilene(®) LP) were tested. All meshes were fixed using 2 ml of each of the three different fibrin glues (TISSUCOL(®), QUIXIL(®), EVICEL(®)) and tested for their biomechanical stability. The defect in the muscle tissue used was 45 mm for a mesh size of 10 × 15 cm. Measurements were conducted using a standardized stamp penetration test, while aiming not to use a fixation strength of less than 32 N.
RESULTS: With TISSUCOL, the fixation of Optilene LP proved to be significantly better than that of TiMESH or ULTRAPRO (97.3 vs. 47.9 vs. 34.9 N, p < 0.001). With EVICEL, it was possible to also achieve good tissue fixation for the ULTRAPRO mesh, while the results obtained for Optilene and TiMESH were relatively poorer [114.7 vs. 92.4 N (p = 0.056), vs. 64.3 N (p < 0.001)]. With QUIXIL, satisfactory results were obtained only for Optilene LP (43.6 N).
CONCLUSION: This study showed that there were significant differences in the fixation strength of different polypropylene meshes in combination with various fibrin glues. Experiments demonstrated that for each mesh there is an optimum combination with a particular fibrin glue with respect to the fixation strength. It must now be verified whether these results can be extrapolated to clinical practice.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22648108     DOI: 10.1007/s00464-012-2339-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  8 in total

1.  Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair.

Authors:  N Katkhouda; E Mavor; M H Friedlander; R J Mason; M Kiyabu; S W Grant; K Achanta; E L Kirkman; K Narayanan; R Essani
Journal:  Ann Surg       Date:  2001-01       Impact factor: 12.969

Review 2.  [Pathophysiology of the abdominal wall].

Authors:  U Klinge; J Conze; W Limberg; C Brücker; A P Ottinger; V Schumpelick
Journal:  Chirurg       Date:  1996-03       Impact factor: 0.955

3.  Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia [International Endohernia Society (IEHS)].

Authors:  R Bittner; M E Arregui; T Bisgaard; M Dudai; G S Ferzli; R J Fitzgibbons; R H Fortelny; U Klinge; F Kockerling; E Kuhry; J Kukleta; D Lomanto; M C Misra; A Montgomery; S Morales-Conde; W Reinpold; J Rosenberg; S Sauerland; C Schug-Pass; K Singh; M Timoney; D Weyhe; P Chowbey
Journal:  Surg Endosc       Date:  2011-07-13       Impact factor: 4.584

4.  A comparative biomechanical evaluation of hernia mesh fixation by fibrin sealant.

Authors:  René H Fortelny; Alexander H Petter-Puchner; James Ferguson; Simone Gruber-Blum; Julian Brand; Kathrin Mika; Heinz Redl
Journal:  J Surg Res       Date:  2010-06-29       Impact factor: 2.192

5.  Different methods of mesh fixation in open retromuscular incisional hernia repair: a comparative study in pigs.

Authors:  J Grommes; M Binnebösel; C D Klink; K T von Trotha; K Junge; J Conze
Journal:  Hernia       Date:  2010-09-12       Impact factor: 4.739

6.  Evaluation of intraperitoneal placement of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant in a New Zealand white rabbit model.

Authors:  Eric D Jenkins; Lora Melman; Salil Desai; Shaun R Brown; Margaret M Frisella; Corey R Deeken; Brent D Matthews
Journal:  Surg Endosc       Date:  2010-07-22       Impact factor: 4.584

7.  Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue.

Authors:  E J Olivier ten Hallers; John A Jansen; Henri A M Marres; Gerhard Rakhorst; Gijsbertus J Verkerke
Journal:  J Biomed Mater Res A       Date:  2007-02       Impact factor: 4.396

8.  Mesh fixation with fibrin glue (Tissucol/Tisseel) in hernia repair dependent on the mesh structure--is there an optimum fibrin-mesh combination?--investigations on a biomechanical model.

Authors:  Christine Schug-Pass; Hans Lippert; Ferdinand Köckerling
Journal:  Langenbecks Arch Surg       Date:  2009-01-31       Impact factor: 3.445

  8 in total
  7 in total

1.  Biomechanical evaluation of fixation properties of fibrin glue for ventral incisional hernia repair.

Authors:  N Stoikes; J Sharpe; H Tasneem; E Roan; E Paulus; B Powell; D Webb; C Handorf; E Eckstein; T Fabian; G Voeller
Journal:  Hernia       Date:  2013-09-24       Impact factor: 4.739

2.  Biomechanical properties of (semi-) synthetic glues for mesh fixation in endoscopic inguinal hernia repair.

Authors:  C Schug-Pass; D A Jacob; J Rittinghausen; H Lippert; F Köckerling
Journal:  Hernia       Date:  2012-10-14       Impact factor: 4.739

3.  Surface modification of polypropylene surgical meshes for improving adhesion with poloxamine hydrogel adhesive.

Authors:  Xinyue Lu; Astha Khanna; Igor Luzinov; Jiro Nagatomi; Melinda Harman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-09-29       Impact factor: 3.368

Review 4.  What do we know about titanized polypropylene meshes? An evidence-based review of the literature.

Authors:  F Köckerling; C Schug-Pass
Journal:  Hernia       Date:  2013-11-20       Impact factor: 4.739

5.  Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs.

Authors:  Gaëtan Guérin; Xavier Bourges; Frédéric Turquier
Journal:  Med Devices (Auckl)       Date:  2014-12-09

Review 6.  Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive-a Laboratory and Clinical Perspective.

Authors:  William D Spotnitz
Journal:  ISRN Surg       Date:  2014-03-04

7.  Assessment of short-term outcome with TiO2 mesh in laparoscopic repair of large paraesophageal hiatal hernias.

Authors:  Islam Khaled; Pablo Priego; Mohammed Faisal; Marta Cuadrado; Francisca García-Moreno; Araceli Ballestero; Julio Galindo; Eduardo Lobo
Journal:  BMC Surg       Date:  2019-10-28       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.