Literature DB >> 22647902

Sensitivity analysis of some critical factors affecting simulated intrusion volumes during a low pressure transient event in a full-scale water distribution system.

G Ebacher1, M C Besner, B Clément, M Prévost.   

Abstract

Intrusion events caused by transient low pressures may result in the contamination of a water distribution system (DS). This work aims at estimating the range of potential intrusion volumes that could result from a real downsurge event caused by a momentary pump shutdown. A model calibrated with transient low pressure recordings was used to simulate total intrusion volumes through leakage orifices and submerged air vacuum valves (AVVs). Four critical factors influencing intrusion volumes were varied: the external head of (untreated) water on leakage orifices, the external head of (untreated) water on submerged air vacuum valves, the leakage rate, and the diameter of AVVs' outlet orifice (represented by a multiplicative factor). Leakage orifices' head and AVVs' orifice head levels were assessed through fieldwork. Two sets of runs were generated as part of two statistically designed experiments. A first set of 81 runs was based on a complete factorial design in which each factor was varied over 3 levels. A second set of 40 runs was based on a latin hypercube design, better suited for experimental runs on a computer model. The simulations were conducted using commercially available transient analysis software. Responses, measured by total intrusion volumes, ranged from 10 to 366 L. A second degree polynomial was used to analyze the total intrusion volumes. Sensitivity analyses of both designs revealed that the relationship between the total intrusion volume and the four contributing factors is not monotonic, with the AVVs' orifice head being the most influential factor. When intrusion through both pathways occurs concurrently, interactions between the intrusion flows through leakage orifices and submerged AVVs influence intrusion volumes. When only intrusion through leakage orifices is considered, the total intrusion volume is more largely influenced by the leakage rate than by the leakage orifices' head. The latter mainly impacts the extent of the area affected by intrusion.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22647902     DOI: 10.1016/j.watres.2012.05.006

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

Review 1.  Microbial Contamination of Drinking Water and Human Health from Community Water Systems.

Authors:  Nicholas J Ashbolt
Journal:  Curr Environ Health Rep       Date:  2015-03

2.  Quantitative Assessment of First Nations Drinking Water Distribution Systems for Detection and Prevalence of Thermophilic Campylobacter Species.

Authors:  Izhar U H Khan; Anita Murdock; Maria Mahmud; Michel Cloutier; Thomas Benoit; Sabrin Bashar; Rakesh Patidar; Ruidong Mi; Bahram Daneshfar; Annemieke Farenhorst; Ayush Kumar
Journal:  Int J Environ Res Public Health       Date:  2022-08-23       Impact factor: 4.614

3.  Effects of hydraulically disconnecting consumer pumps in an intermittent water supply.

Authors:  David D J Meyer; J Khari; Andrew J Whittle; Alexander H Slocum
Journal:  Water Res X       Date:  2021-06-18

4.  Analytical scaling relations to evaluate leakage and intrusion in intermittent water supply systems.

Authors:  David D J Taylor; Alexander H Slocum; Andrew J Whittle
Journal:  PLoS One       Date:  2018-05-18       Impact factor: 3.240

5.  Continuous and Real-Time Detection of Drinking-Water Pathogens with a Low-Cost Fluorescent Optofluidic Sensor.

Authors:  João Simões; Tao Dong
Journal:  Sensors (Basel)       Date:  2018-07-10       Impact factor: 3.576

  5 in total