AIMS: The aims of the study were to determine human breast milk adiponectin concentration and to investigate its relationship with serum adiponectin concentration in lactating mothers and their infants and also to evaluate the relationship between serum adiponectin concentration and anthropometric parameters in nurses and infants. METHODS: We enrolled 60 healthy term breastfed (BF) infants and their lactating mothers. Adiponectin was determined by radioimmunoassay test in serum and by enzyme-linked immunosorbent assay test in human milk (HM). Infants' and mothers' anthropometric parameters were measured. RESULTS: Median (25‰, 75‰) adiponectin concentration in HM was 9.99 (3.59, 20.52) ng/mL. Serum adiponectin concentration in infants was 60.49 (45.76, 74.24) μg/mL and in lactating mothers 21.14 (12.61, 29.66) μg/mL. Adiponectin concentration in HM correlated positively with adiponectin in mothers' serum; r = 0.60 (p < 0.001) and in infants' serum r = 0.37 (p = 0.015). Adiponectin in HM correlated negatively with infants' age r = -0.3 (p = 0.04). Infants' serum adiponectin correlated negatively with their weight r = -0.35 (p = 0.005), length r = -0.35 (p = 0.006) and age r = -0.46 (p < 0.001) and mothers' serum adiponectin with their weight r = -0.37 (p = 0.02) and body mass index r = -0.45 (p = 0.004). CONCLUSIONS: The observed correlations between adiponectin in mothers, HM and BF infants may be suggestive for a metabolic link between nurses and infants through milk.
AIMS: The aims of the study were to determine human breast milk adiponectin concentration and to investigate its relationship with serum adiponectin concentration in lactating mothers and their infants and also to evaluate the relationship between serum adiponectin concentration and anthropometric parameters in nurses and infants. METHODS: We enrolled 60 healthy term breastfed (BF) infants and their lactating mothers. Adiponectin was determined by radioimmunoassay test in serum and by enzyme-linked immunosorbent assay test in human milk (HM). Infants' and mothers' anthropometric parameters were measured. RESULTS: Median (25‰, 75‰) adiponectin concentration in HM was 9.99 (3.59, 20.52) ng/mL. Serum adiponectin concentration in infants was 60.49 (45.76, 74.24) μg/mL and in lactating mothers 21.14 (12.61, 29.66) μg/mL. Adiponectin concentration in HM correlated positively with adiponectin in mothers' serum; r = 0.60 (p < 0.001) and in infants' serum r = 0.37 (p = 0.015). Adiponectin in HM correlated negatively with infants' age r = -0.3 (p = 0.04). Infants' serum adiponectin correlated negatively with their weight r = -0.35 (p = 0.005), length r = -0.35 (p = 0.006) and age r = -0.46 (p < 0.001) and mothers' serum adiponectin with their weight r = -0.37 (p = 0.02) and body mass index r = -0.45 (p = 0.004). CONCLUSIONS: The observed correlations between adiponectin in mothers, HM and BF infants may be suggestive for a metabolic link between nurses and infants through milk.
Authors: Camille R Schneider-Worthington; Jessica S Bahorski; David A Fields; Barbara A Gower; José R Fernández; Paula C Chandler-Laney Journal: J Hum Lact Date: 2020-10-09 Impact factor: 2.219
Authors: Nicholas J Andreas; Matthew J Hyde; Chris Gale; James R C Parkinson; Suzan Jeffries; Elaine Holmes; Neena Modi Journal: PLoS One Date: 2014-12-23 Impact factor: 3.240
Authors: Gabriela E Leghi; Merryn J Netting; Ching T Lai; Ardra Narayanan; Michael Dymock; Alethea Rea; Mary E Wlodek; Donna T Geddes; Beverly S Muhlhausler Journal: Nutrients Date: 2021-05-31 Impact factor: 5.717