Atmospheric concentration and deposition samples were collected between June 2008 and June 2009 in an urban sampling site Yavuzselim, Turkey. Eighty-three polychlorinated biphenyl (PCB) congeners were targeted in the collected samples. It was found that 90% of the total PCB concentration was in the gas phase. Deposition samples were collected by a wet-dry deposition sampler (WDDS) and a bulk deposition sampler (BDS). Average total deposition fluxes measured with the BDS in dry periods was 5500 ± 2400 pg/(m(2)day); average dry deposition fluxes measured by the WDDS in the same period were 6400 ± 3300 pg/(m(2)day). The results indicated that the sampler type affected the measured flux values. Bulk deposition samples were also collected in rainy periods by using the BDS and the average flux value was 8700 ± 3100 pg/(m(2)day). The measured flux values were lower than the values reported for the urban and industrial areas. Dry deposition velocities for the WDDS and BDS samples were calculated 0.48 ± 0.35 cm/s and 0.13 ± 0.15 cm/s, respectively.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22629199 PMCID: PMC3353559 DOI: 10.1100/2012/798020
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Measured meteorological data during the sampling period.
| Number | Sampling period | Avg. temperature (°C) | Avg. wind speed (m/s) | Dominant wind direction | Avg. humidity (%) | Rain volume ( |
|---|---|---|---|---|---|---|
| 1 | 11.06–18.06.2008 | 24 ± 4 | 0.9 ± 1.0 | WNW | 48 ± 13 | 0 |
| 2 | 18.06–30.06.2008 | 27 ± 4 | 1.6 ± 1.0 | NE | 47 ± 13 | 0 |
| 3 | 30.06–16.07.2008 | 26 ± 4 | 1.7 ± 1.0 | N | 44 ± 11 | 0 |
| 4 | 16.07–01.08.2008 | 25 ± 4 | 1.5 ± 1.1 | WNW | 54 ± 14 | 0 |
| 5 | 01.08–15.08.2008 | 26 ± 4 | 1.7 ± 1.0 | ENE | 48 ± 11 | 0 |
| 6 | 15.08–01.09.2008 | 27 ± 4 | 1.5 ± 1.1 | NE | 55 ± 13 | 0 |
| 7 | 01.09–16.09.2008 | 24 ± 4 | 1.2 ± 0.9 | WNW | 53 ± 13 | 0.4 |
| 8 | 16.09–16.10.2008 | 17 ± 4 | 0.9 ± 1.1 | WNW | 72 ± 15 | 7 |
| 9 | 16.10–03.11.2008 | 16 ± 3 | 0.6 ± 0.7 | NE | 72 ± 12 | 0 |
| 10 | 03.11–17.11.2008 | 14 ± 3 | 0.7 ± 0.7 | WNW | 81 ± 10 | 0.25 |
| 11 | 17.11–01.12.2008 | 12 ± 5 | 2.3 ± 2.6 | SE | 69 ± 17 | 13.4 |
| 12 | 01.12–16.12.2008 | 11 ± 5 | 1.4 ± 1.1 | E | 64 ± 13 | 0.28 |
| 13 | 16.12–02.01.2009 | 5 ± 4 | 1.3 ± 1.0 | ENE | 77 ± 9 | 10.9 |
| 14 | 02.01–17.01.2009 | 5 ± 3 | 1.3 ± 0.9 | E | 68 ± 13 | 16.2 |
| 15 | 17.01–02.02.2009 | 10 ± 5 | 1.5 ± 1.7 | ENE | 66 ± 14 | 1.9 |
| 16 | 02.02–17.02.2009 | 10 ± 5 | 1.8 ± 1.8 | WNW | 71 ± 17 | 19.5 |
| 17 | 17.02–02.03.2009 | 5 ± 3 | 1.2 ± 1.0 | ENE | 76 ± 10 | 4 |
| 18 | 02.03–16.03.2009 | 10 ± 5 | 1.9 ± 2.0 | WNW | 71 ± 17 | 10 |
| 19 | 16.03–01.04.2009 | 9 ± 5 | 1.5 ± 1.6 | WNW | 66 ± 16 | 7 |
| 20 | 01.04–17.04.2009 | 12 ± 4 | 1.1 ± 0.9 | WNW | 72 ± 18 | 1 |
| 21 | 17.04–01.05.2009 | 14 ± 5 | 1.1 ± 1.0 | WNW | 67 ± 15 | 0.6 |
| 22 | 01.05–16.05.2009 | 17 ± 4 | 1.1 ± 1.1 | WNW | 62 ± 17 | 0 |
| 23 | 16.05–01.06.2009 | 20 ± 4 | 1.2 ± 1.0 | WNW | 57 ± 15 | 0 |
| 24 | 01.06–16.06.2009 | 24 ± 4 | 1.3 ± 1.1 | WNW | 57 ± 16 | 0 |
Figure 1Schematic display of wet dry deposition sampler (WDDS) and bulk deposition sampler (BDS).
Recovery efficiencies for the HVAS and BDS samplers.
| Congeners | HVAS | WDDS | BDS | ||
|---|---|---|---|---|---|
| Filter | PUF | Filter | Resin | ||
| PCB#14 | 56.16 ± 14.79 | 70.22 ± 23.52 | 50.45 ± 25.83 | 47.16 ± 17.70 | 54.20 ± 11.46 |
| PCB#65 | 62.50 ± 17.19 | 64.22 ± 18.33 | 67.47 ± 19.62 | 58.57 ± 18.78 | 77.25 ± 19.85 |
| PCB#166 | 75.60 ± 23.20 | 77.44 ± 22.67 | 88.26 ± 26.55 | 72.30 ± 22.38 | 92.00 ± 17.74 |
Atmospheric concentrations of PCBs at various locations.
| Location | Period |
| Concentration (pg/m3) | Reference | |
|---|---|---|---|---|---|
| Paris, France | (Urban) | 1989-1990 | 12 | 2000–6000 | [ |
| Cumbria, UK | (Coastal) | 1996-1997 | 52 | 318 | [ |
| Athens, Greece | (Urban) | 2000 July | 38 | 344.9 |
[ |
| (Coastal) | 181.1 | ||||
| Thessaloniki, Greece | (Rural) | March 1999 | 6 | 0.5–29.2 |
[ |
| (Semirural) | October 1999 | 0.5–15.6 | |||
| Zagreb, Croatia | (Urban) | June 1999 | 20 | 8.2–968.6 (gas) |
[ |
| February 2000 | 11.2–859.1 (particle) | ||||
| Madrid, Spain | (Urban) | February 1998 | 31 | 120–4300 |
[ |
| June 1998 | |||||
| Stockholm, Sweden | (Urban) | 1991–1996 | 63 | 3300–6800 |
[ |
| Ansung, Korea | (Rural) | July 1999 | 38 | 6.13–71.9 |
[ |
| June 2000 | |||||
| Venice Lagoon | (Urban) | August 2002 | 54 | 421 (gas) |
[ |
| September 2002 | 11 (particle) | ||||
| Elm Road, England | (Semirural) | April 1999 | 12 | 252 (gas + particle) |
[ |
| July 2000 | |||||
| Chicago, USA | (Urban) | June 1995 | 50 | 1820 (gas) |
[ |
| October 1995 | 90 (particle) | ||||
| Eordea, Greece | (Industrial) | January 2001 | 8 | 0.04–103 (particle) |
[ |
| June 2001 | |||||
| Yokohama, Japan | (Urban) | March 2002 | 12 | 62–250 (gas + particle) |
[ |
| February 2003 | |||||
| Uludag University Campus, Turkey | (Semirural) | July 2004 | 24 | 328 ± 284 (gas) |
[ |
| May 2005 | 86 ± 128 (particle) | ||||
| Yavuzselim, Turkey | (Residential) | June 2008 | 83 | 320 ± 110 (gas) | This study |
| June 2009 | 40 ± 30 (particle) |
Figure 2Distribution of the average gas/particulate concentrations of the PCB congeners.
Dry and bulk deposition flux values obtained at different sampling site.
| Sampling site | Period |
| Flux (ng/(m2day)) | Sampler type | Reference |
|---|---|---|---|---|---|
| Dry deposition | |||||
|
| |||||
| Paris, France (Urban) | 1989 | 12 | 79 | Stainless-steel funnel | [ |
| Sleeping Bear Dunes, MI, USA (Rural) | 1993–1995 | 44 | 60 | Mylar strips, Apiezon L. grease | [ |
| Chicago, IL, USA (Urban) | June–October 1995 | — | 240 | WSS | [ |
| Bursa, Turkey (Suburban) | July 2004–May 2005 | 41 | 40.6 ± 40.6 | WSS | [ |
| Bursa, Turkey (Urban, Traffic site) | July 2004–May 2005 | 41 | 86.0 ± 97.4 | WSS | [ |
| Yavuzselim, Bursa, Turkey (Residential) | June 2008–June 2009 | 83 | 5.50 ± 2.50 | WDDS | This study |
|
| |||||
| Bulk deposition | |||||
|
| |||||
| P. Marghera. Italy (Industrial) | 1998-1999 | — | 7.3 | Pyrex funnel | [ |
| Valle Figeri Italy (Far-clean) | 1998-1999 | — | 1.5 | Pyrex funnel | [ |
| Tsukuba. Japan (Semirural) | 1997-1998 | 12 | 0.3 | Stainless-steel vessel | [ |
| Galveston Bay. USA (Coastal) | Feb. 1995–Aug. 1996 | 22 | 17.5 | Wet deposition and calculation | [ |
| BOID Bursa. TR (Urban/Industrial) | July 2004–May 2005 | 41 | 15.4 ± 14.3 | Stainless-steel vessel | [ |
| Gülbahçe, TR (Urban) | July 2004–May 2005 | 41 | 36.1 ± 21.3 | Stainless-steel vessel | [ |
| Yavuzselim, TR (Residential) | June 2008–June 2009 | 83 | 7.20 ± 3.50 | Stainless-steel vessel | This study |
*F = V × C (V = 0.2 cm/s).
Figure 3Temporal variation of dry and bulk deposition flux values.
Figure 4PCB homolog distribution of dry deposition flux samples.
Figure 5(a) Relationship between WDDS homolog distributions and BDS homolog distributions, and (b) relationship between rainy period bulk deposition fluxes and rain volumes.