Literature DB >> 22626826

Bi-enzyme L-arginine-selective amperometric biosensor based on ammonium-sensing polyaniline-modified electrode.

Nataliya Stasyuk1, Oleh Smutok, Galina Gayda, Bohdan Vus, Yevgen Koval'chuk, Mykhailo Gonchar.   

Abstract

A novel L-arginine-selective amperometric bi-enzyme biosensor based on recombinant human arginase I isolated from the gene-engineered strain of methylotrophic yeast Hansenula polymorpha and commercial urease is described. The biosensing layer was placed onto a polyaniline-Nafion composite platinum electrode and covered with a calcium alginate gel. The developed sensor revealed a good selectivity to L-arginine. The sensitivity of the biosensor was 110 ± 1.3 nA/(mM mm(2)) with the apparent Michaelis-Menten constant (K(M)(app)) derived from an L-arginine (L-Arg) calibration curve of 1.27 ± 0.29 mM. A linear concentration range was observed from 0.07 to 0.6mM, a limit of detection being 0.038 mM and a response time - 10s. The developed biosensor demonstrated good storage stability. A laboratory prototype of the proposed amperometric biosensor was applied to the samples of three commercial pharmaceuticals ("Tivortin", "Cytrarginine", "Aminoplazmal 10% E") for L-Arg testing. The obtained L-Arg-content values correlated well with those declared by producers.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22626826     DOI: 10.1016/j.bios.2012.04.031

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Reagentless electrochemical biosensors through incorporation of unnatural amino acids on the protein structure.

Authors:  Elnaz Zeynaloo; Elsayed M Zahran; Yu-Ping Yang; Emre Dikici; Trajen Head; Leonidas G Bachas; Sylvia Daunert
Journal:  Biosens Bioelectron       Date:  2021-12-07       Impact factor: 12.545

2.  Fabrication of a Urea Biosensor for Real-Time Dynamic Fluid Measurement.

Authors:  Kyunghee Kim; Jeongeun Lee; Bo Mi Moon; Ye Been Seo; Chan Hum Park; Min Park; Gun Yong Sung
Journal:  Sensors (Basel)       Date:  2018-08-09       Impact factor: 3.576

Review 3.  L-arginine biosensors: A comprehensive review.

Authors:  Neelam Verma; Ashish Kumar Singh; Minni Singh
Journal:  Biochem Biophys Rep       Date:  2017-11-06

4.  The Synergy of Thermally Reduced Graphene Oxide in Amperometric Urea Biosensor: Application for Medical Technologies.

Authors:  Julija Razumiene; Vidute Gureviciene; Ieva Sakinyte; Laurynas Rimsevicius; Valdas Laurinavicius
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.