Evaluation of a prototype for a reference platelet counter.

S M Lewis1, R M Rowan, F Kubota.   

Abstract

A semiautomated single channel aperture-impedance particle counter was developed as a prototype for a reference platelet count for assigning values to reference preparations used in automated blood cell counts. The instrument is equipped with sheath flow and an aperture orifice of 50 microns in diameter and 60 microns in length to eliminate non-axial flow and minimise coincidence errors. Use of fixed volume and red blood cell:platelet ratios obviate dilution errors. The counter was assessed in accordance with the International Committee for Standardization in Haematology protocol for evaluation of automated blood cell counters. The counter provided a high level of linearity and precision, accurate coincidence correction, controlled volume, stability and negligible carryover.

Mesh:

Year:  1990        PMID: 2262564      PMCID: PMC502906          DOI: 10.1136/jcp.43.11.932

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  Coincidence correction in red blood cell counting.

Authors:  S M Lewis; J M England; F Kubota
Journal:  Phys Med Biol       Date:  1989-09       Impact factor: 3.609

2.  A revised scheme for the evaluation of automatic instruments for use in clinical chemistry.

Authors:  P M Broughton; A H Gowenlock; J J McCormack; D W Neill
Journal:  Ann Clin Biochem       Date:  1974-11       Impact factor: 2.057

3.  Platelet counting-development of a reference method and a reference preparation.

Authors:  S M Lewis; J Wardle; S Cousins; J V Skelly
Journal:  Clin Lab Haematol       Date:  1979

4.  A rapid and accurate differential centrifugation method for platelet counts.

Authors:  S Cousins; S M Lewis
Journal:  J Clin Pathol       Date:  1982-01       Impact factor: 3.411

5.  Automated platelet counting--a re-evaluation of the sedimentation method.

Authors:  S M Lewis; J V Skelly; S Cousins
Journal:  Clin Lab Haematol       Date:  1981
  5 in total
  2 in total

1.  Current concerns in haematology. 3: Blood count calibration.

Authors:  S M Lewis; J M England; R M Rowan
Journal:  J Clin Pathol       Date:  1991-11       Impact factor: 3.411

2.  Statistical analysis of comparison between laboratory methods.

Authors:  D G Altman
Journal:  J Clin Pathol       Date:  1991-08       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.