Literature DB >> 22624897

Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope.

Katrin Petermeier1, Daniela Suesskind, Elke Altpeter, Andreas Schatz, André Messias, Florian Gekeler, Peter Szurman.   

Abstract

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs).
SETTING: University Eye Hospital, Tuebingen, Germany.
DESIGN: Case series.
METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes.
RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217).
CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22624897     DOI: 10.1016/j.jcrs.2011.12.027

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Morphological changes in the iridocorneal angle and their relationship with intraocular pressure after infantile cataract surgery.

Authors:  Dan-Dan Wang; Zhang-Liang Li; Bing Zhang; Zi-Yi Lu; Wei-Chen Guan; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2022-09-18       Impact factor: 1.645

2.  Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography.

Authors:  Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa
Journal:  Eye Vis (Lond)       Date:  2020-08-16

3.  Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations.

Authors:  Daisuke Kunita; Makoto Inoue; Yuji Itoh; Naoko Matsuki; Toshiyuki Nagamoto; Akito Hirakata
Journal:  BMC Ophthalmol       Date:  2017-06-02       Impact factor: 2.209

4.  Changes in symmetry of anterior chamber following routine cataract surgery in non-glaucomatous eyes.

Authors:  Hanbin Lee; Ieva Zukaite; Valerie Juniat; Maria E Dimitry; Amanda Lewis; Mayank A Nanavaty
Journal:  Eye Vis (Lond)       Date:  2019-07-03

5.  Outcomes of the EVO ICL Using a Customized Non-horizontal or Horizontal Implanting Orientation Based on UBM Measurement: A Pilot Study.

Authors:  Ruoyan Wei; Mingrui Cheng; Lingling Niu; Lin Wang; Xiumei Luo; Meiyan Li; Xiaodong Zhou; Xiaoying Wang; Xingtao Zhou; Peijun Yao
Journal:  Ophthalmol Ther       Date:  2022-04-12

6.  Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes.

Authors:  Ruoyan Wei; Meiyan Li; Aruma Aruma; Michael C Knorz; Dong Yang; Yongfu Yu; Xiaoying Wang; Joanne Choi; Peijun Yao; Xingtao Zhou
Journal:  J Cataract Refract Surg       Date:  2022-03-30       Impact factor: 3.528

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.