Literature DB >> 22624676

Long-term experience of patch graft failure after Ahmed Glaucoma Valve® surgery using donor dura and sclera allografts.

Alan H Zalta1.   

Abstract

BACKGROUND AND
OBJECTIVE: To report the long-term incidence, timing, and experience of patch graft failure (PGF) after Ahmed Glaucoma Valve (AGV) (New World Medical, Inc., Rancho Cucamonga, CA) surgery in a large consecutive case series using donor dura mater and sclera sequentially as the allograft materials. PATIENTS AND METHODS: The medical records of all AGV surgeries performed from June 1994 through December 2010 were retrospectively reviewed for cases of PGF.
RESULTS: Patch graft failure occurred in 44 (6.3%) of the initial 695 procedures using dura and in 65 (5.8%) of the subsequent 1,121 procedures using sclera (P = .64). The time interval after AGV surgery until the occurrence of PGF was significantly longer for dura (5.8 ± 3.8 years) than for sclera (2.7 ± 1.9 years) (P < .001).
CONCLUSION: After an average of 4 years, PGF occurred in 109 (6%) of 1,816 consecutive AGV surgeries using donor dura and sclera allografts. PGF may be the most frequent long-term complication after AGV surgery. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22624676     DOI: 10.3928/15428877-20120517-01

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  5 in total

Review 1.  Childhood glaucoma surgery in the 21st century.

Authors:  M Papadopoulos; B Edmunds; C Fenerty; P T Khaw
Journal:  Eye (Lond)       Date:  2014-06-13       Impact factor: 3.775

2.  Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study.

Authors:  Q Pan; H D Jampel; P Ramulu; G F Schwartz; F Cotter; D Cute; Y J Daoud; P Murakami; W J Stark
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

3.  Glaucoma Patch Graft Surgery Utilizing Corneas Augmented with Collagen Cross-linking.

Authors:  Donald U Stone; Earl Randy Craven; Sameer I Ahmad; Ali AlBeshri; Ohoud A Owaidhah
Journal:  Middle East Afr J Ophthalmol       Date:  2019-09-30

4.  Comparison of Locally Sourced Pericardium and Other Conventional Patch Graft Materials in a Glaucoma Drainage Device Surgery.

Authors:  Shruti Aggarwal; Candice Kremer; Stephanie Engelhard; Sandra Johnson
Journal:  J Curr Glaucoma Pract       Date:  2021 Jan-Apr

5.  Donor Cornea Use in Scleral Surface Reconstruction

Authors:  Ayşe Burcu; Züleyha Yalnız-Akkaya; Evin Şingar Özdemir; Selma Özbek-Uzman
Journal:  Turk J Ophthalmol       Date:  2021-08-27
  5 in total