Literature DB >> 22622239

Association between degenerative spondylolisthesis and spinous process fracture after interspinous process spacer surgery.

David H Kim1, Nael Shanti, Mark E Tantorski, Jeremy D Shaw, Ling Li, Juli F Martha, Adrian J Thomas, Stephen J Parazin, Tal C Rencus, Brian Kwon.   

Abstract

BACKGROUND CONTEXT: Spinous process fracture is a recognized complication associated with interspinous process spacer (IPS) surgery. Although occasionally identified by plain radiographs, computed tomography (CT) appears to identify a higher rate of such fractures. Although osteoporotic insufficiency fracture is considered a contraindication for IPS surgery, a formal risk factor analysis for this complication has not previously been reported.
PURPOSE: To identify risk factor(s) associated with early spinous process fracture after IPS surgery. STUDY DESIGN/
SETTING: Prospective cohort study of 39 consecutive patients with lumbar stenosis and neurogenic claudication undergoing IPS surgery at a single institution.
METHODS: Patients underwent preoperative dual-energy X-ray absorptiometry (DXA) scans, lumbar spine CT, and plain radiographs. Postoperatively, patients underwent repeat CT imaging within 6 months of surgery and serial radiographs at 2 weeks, 6 weeks, 3 months, 6 months, and 1 year. Preoperative CT scans were analyzed by calculating average Hounsfield units for a 1 cm(2) area of the midsagittal reconstructed image for four separate locations: midvertebral body, subcortical bone subjacent to the superior margin of the midspinous process, subcortical bone above the inferior margin of the midspinous process, and the midspinous process.
RESULTS: Thirty-eight patients underwent IPS surgery at a total of 50 levels (38 L4-L5, 12 L3-L4; 26 one-level, 12 two-level). One patient underwent laminectomy at index surgery and was excluded from the analysis. Implants included 34 titanium X-STOP (Medtronic, Memphis, TN, USA), 8 polyaryletheretherketone X-STOP (Medtronic, Memphis, TN, USA), and 8 Aspen (Lanx, Broomfield, CO, USA) devices. Eleven spinous process fractures were identified by CT in 11 patients (22.0% of levels). No fractures were apparent on plain radiographs. The rate of spondylolisthesis observed on preoperative radiographs was 100% (11 of 11) among patients with fractures compared with 33.3% (9 of 27) of patients without fracture (p=.0001). Overall, 21 of 39 patients in this series had spondylolisthesis, and the rate of fracture in this group was 52%. Among patients without spondylolisthesis, the fracture rate was 0%. A trend was observed toward decreased DXA lumbar spine and hip T-scores among fracture patients versus nonfracture patients (0.2 ± 1.7 vs. 0.8 ± 1.7; p=.389; -1.1 ± 1.4 vs. -0.3 ± 1.4; p=.201), but these differences were not significant. Similarly, bone density based on CT measurements at four different locations revealed a trend toward decreased density among fracture patients, but these differences were not significant.
CONCLUSIONS: Degenerative spondylolisthesis appears strongly associated with the occurrence of spinous process fracture after IPS surgery. There is a trend toward increased fracture risk in patients with decreased bone mineral density as measured by both DXA scan and CT-based volume averaging of Hounsfield units, but osteoporosis appears to be a relatively weaker risk factor. The association between spondylolisthesis and fracture observed in this study may account for the relatively poorer outcome of IPS surgery in patients with spondylolisthesis that has been reported in previous series.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22622239     DOI: 10.1016/j.spinee.2012.03.034

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  16 in total

1.  Motion characteristics of the lumbar spinous processes with degenerative disc disease and degenerative spondylolisthesis.

Authors:  Qi Yao; Shaobai Wang; Jae-Hyuk Shin; Guoan Li; Kirkham Wood
Journal:  Eur Spine J       Date:  2013-08-02       Impact factor: 3.134

2.  Let'X-STOP with any "distraction" from the true problem: scenarios in which minimally invasive surgery is not welcome!

Authors:  Tobias A Mattei
Journal:  Neurosurg Rev       Date:  2012-12-18       Impact factor: 3.042

Review 3.  Minimally invasive spine surgery: systematic review.

Authors:  Péter Banczerowski; Gábor Czigléczki; Zoltán Papp; Róbert Veres; Harry Zvi Rappaport; János Vajda
Journal:  Neurosurg Rev       Date:  2014-09-10       Impact factor: 3.042

4.  Interspinous posterior devices: What is the real surgical indication?

Authors:  Alessandro Landi
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

Review 5.  Osteoporosis and the Management of Spinal Degenerative Disease (I).

Authors:  Félix Tomé-Bermejo; Angel R Piñera; Luis Alvarez-Galovich
Journal:  Arch Bone Jt Surg       Date:  2017-09

6.  Greater than 5-year follow-up of outpatient L4-L5 lumbar interspinous fixation for degenerative spinal stenosis using the INSPAN device.

Authors:  Kingsley R Chin; Fabio J R Pencle; Amala Benny; Jason A Seale
Journal:  J Spine Surg       Date:  2020-09

7.  Bone resorption during the first year after implantation of a single-segment dynamic interspinous stabilization device and its risk factors.

Authors:  Kaifeng Wang; Zhenqi Zhu; Bo Wang; Yi Zhu; Haiying Liu
Journal:  BMC Musculoskelet Disord       Date:  2015-05-14       Impact factor: 2.362

8.  Grade 1 spondylolisthesis and interspinous device placement: removal in six patients and analysis of current data.

Authors:  Parker E Bohm; Karen K Anderson; Elizabeth A Friis; Paul M Arnold
Journal:  Surg Neurol Int       Date:  2015-04-02

9.  Percutaneous interspinous distraction device for the treatment of lumbar spinal canal stenosis: clinical and radiographic results at 2-year follow-up.

Authors:  Wicharn Yingsakmongkol; Chaiyos Chaichankul; Worawat Limthongkul
Journal:  Int J Spine Surg       Date:  2014-12-01

10.  Lumbar Interspinous Process Fixation and Fusion with Stand-Alone Interlaminar Lumbar Instrumented Fusion Implant in Patients with Degenerative Spondylolisthesis Undergoing Decompression for Spinal Stenosis.

Authors:  Franco Postacchini; Roberto Postacchini; Pier Paolo Maria Menchetti; Pasquale Sessa; Michela Paolino; Gianluca Cinotti
Journal:  Asian Spine J       Date:  2016-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.