Blinded measure of Trendelenburg angle in pelvic robotic surgery.

Claire Gould1, Thomas Cull, Ying Xing Wu, Blake Osmundsen.   

Abstract

STUDY
OBJECTIVE: To estimate the Trendelenburg angle needed to perform robotic gynecologic surgical procedures.
DESIGN: Cross-sectional study (Canadian Task Force classification III).
SETTING: Community hospital. PATIENTS: All women undergoing gynecologic pelvic surgery using the da Vinci surgical robot at a single institution between December 2010 and April 2011.
INTERVENTIONS: The primary surgeon determined the Trendelenburg angle needed for adequate visualization to perform surgery defined as small bowel and sigmoid colon displaced out of the surgical field.
MEASUREMENTS AND MAIN RESULTS: The primary outcome, measured in blinded fashion, was the degree of Trendelenburg positioning needed to complete the surgical procedure robotically. Secondary data collected included body mass index, type of surgery performed, maximum end-tidal CO(2), and maximum peak inspiratory pressure. Sixteen surgeons performed a total of 104 robotic gynecologic pelvic surgeries during the study. Data were available for 86 cases. The mean Trendelenburg angle used was 28.0 degrees (95% confidence interval, 26.9-29.1). This was significantly less than the 40 degrees (p < .001) commonly recommended. The Trendelenburg angle used did not correlate with body mass index (r = -0.2; p = .13) or type of surgery performed (p = .41). Neither the maximum end-tidal CO(2) or maximum peak inspiratory pressure was influenced by the Trendelenburg angle used when adjusted for age and body mass index.
CONCLUSIONS: A mean Trendelenburg angle of 28.0 degrees was adequate to complete most gynecologic robotic surgical procedures when compared with historical control angle of 40 degrees.
Copyright © 2012 AAGL. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22621993     DOI: 10.1016/j.jmig.2012.03.014

Source DB:  PubMed          Journal:  J Minim Invasive Gynecol        ISSN: 1553-4650            Impact factor:   4.137


  4 in total

1.  The effect of steep head-down tilt on respiratory status in endometrial cancer patients with obesity during robot-assisted hysterectomy.

Authors:  Akira Mitsuhashi; Hiroshi Ishikawa; Yuji Habu; Hirokazu Usui
Journal:  Gynecol Oncol Rep       Date:  2022-05-30

2.  Quantitative rise in intraocular pressure in patients undergoing robotic surgery in steep Trendelenburg position: A prospective observational study.

Authors:  Nitesh Goel; Itee Chowdhury; Jitendra Dubey; Amit Mittal; Soumi Pathak
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-01-18

3.  Effects of -10° and -30° head-down tilt on cerebral blood velocity, dynamic cerebral autoregulation, and noninvasively estimated intracranial pressure.

Authors:  Tomokazu Kato; Takuya Kurazumi; Toru Konishi; Chiharu Takko; Yojiro Ogawa; Ken-Ichi Iwasaki
Journal:  J Appl Physiol (1985)       Date:  2022-02-24

4.  A prospective observational study on changes in endo-tracheal tube cuff pressure and its correlation with airway pressures during various stages of robotic pelvic surgeries.

Authors:  Priyanka Gupta; Shipra Tandon; Mridul Dhar; Ankit Agarwal; Sharmishtha Pathak; P Prabakaran
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2022-07-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.