Ileal low-pressure bladder replacement: Camey type II. Stapling technique and preliminary results (57 cases, 1987-1989).

P Leandri1, G Rossignol, J R Gautier, H Quintens, E Lasserre, J Caissel.   

Abstract

In keeping with the basic principles of Camey's procedure and with a view to improve continence, we decided in 1987 to experiment with the technique of ileal low-pressure bladder replacement (Camey II). We introduced the stapling technique in order to save time and to obtain watertight, reliable sutures. 57 patients underwent a Camey II intervention following radical cystectomy. Follow-up was 3-24 months. No operation mortality was observed and only 5 perioperative complications were recorded. Continence during the day and at night increased rapidly with Camey II (50% at 3 months, 90% at 6 months). Camey II improves the patients' quality of life; the procedure is simple, fast and reliable thanks to the stapling technique.

Entities:  

Mesh:

Year:  1990        PMID: 2261926     DOI: 10.1159/000463900

Source DB:  PubMed          Journal:  Eur Urol        ISSN: 0302-2838            Impact factor:   20.096


  2 in total

1.  Bladder replacement with modified Studer pouch using absorbable staples.

Authors:  M Cecchi; C A Sepich; G Pagni; L Fiorentini
Journal:  Int Urol Nephrol       Date:  1997       Impact factor: 2.370

2.  Chronic ischaemia of the ileal neobladder: clinical manifestations and management.

Authors:  H M Alemayehu; M Hornák; A Bárdos
Journal:  Int Urol Nephrol       Date:  1994       Impact factor: 2.370

  2 in total