MSCT follow-up in malignant lymphoma: comparison of manual linear measurements with semi-automated lymph node analysis for therapy response classification.

J Weßling1, M Puesken, R Koch, N Kohlhase, T Persigehl, R Mesters, W Heindel, B Buerke.   

Abstract

PURPOSE: Assignment of semi-automated lymph node analysis compared to manual measurements for therapy response classification of malignant lymphoma in MSCT.
MATERIALS AND METHODS: MSCT scans of 63 malignant lymphoma patients before and after 2 cycles of chemotherapy (307 target lymph nodes) were evaluated. The long axis diameter (LAD), short axis diameter (SAD) and bi-dimensional WHO were determined manually and semi-automatically. The time for manual and semi-automatic segmentation was evaluated. The ref. standard response was defined as the mean relative change across all manual and semi-automatic measurements (mean manual/semi-automatic LAD, SAD, semi-automatic volume). Statistical analysis encompassed t-test and McNemar's test for clustered data.
RESULTS: Response classification per lymph node revealed semi-automated volumetry and bi-dimensional WHO to be significantly more accurate than manual linear metric measurements. Response classification per patient based on RECIST revealed more patients to be correctly classified by semi-automatic measurements, e. g. 96.0 %/92.9 % (WHO bi-dimensional/volume) compared to 85.7/84.1 % for manual LAD and SAD, respectively (mean reduction in misclassified patients of 9.95 %). Considering the use of correction tools, the time expenditure for lymph node segmentation (29.7 ± 17.4 sec) was the same as with the manual approach (29.1 ± 14.5 sec).
CONCLUSION: Semi-automatically derived "lymph node volume" and "bi-dimensional WHO" significantly reduce the number of misclassified patients in the CT follow-up of malignant lymphoma by at least 10 %. However, lymph node volumetry does not outperform bi-dimensional WHO. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 22618478     DOI: 10.1055/s-0032-1312751

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  2 in total

1.  Comparison of manual and semi-automatic measuring techniques in MSCT scans of patients with lymphoma: a multicentre study.

Authors:  A J Höink; J Weßling; R Koch; C Schülke; N Kohlhase; L Wassenaar; R M Mesters; M D'Anastasi; M Fabel; A Wulff; D Pinto dos Santos; A Kießling; A Graser; V Dicken; M Karpitschka; L Bornemann; W Heindel; B Buerke
Journal:  Eur Radiol       Date:  2014-09-06       Impact factor: 5.315

2.  [Automatic segmentation and annotation in radiology].

Authors:  P Dankerl; A Cavallaro; M Uder; M Hammon
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.