Literature DB >> 2261697

Evaluation of a simple method for the measurement of cytidine deaminase in serum and comparison with a reference method.

P W Thompson1, I T James, L Rowell, D D Jones.   

Abstract

This study was designed to evaluate a cytidine deaminase (CD) assay modified to allow results to be achieved within one working day. Inter-batch variation for samples of mean (SD) CD activity, 10.2 (1.0) units, 17.5 (1.2) units and 31.7 (1.7) units were, 9.8%, 6.9% and 5.4% respectively (n = 26). The reference range (3.2-13.2 U) was similar in males and females and was independent of age. There was close correlation with a reference method (r = 0.96). The mean difference between methods was 2.7 U and the limits of agreement were -1.7 to 7.1 U. The results indicate that the short assay technique can produce results that are sufficiently accurate and precise to be clinically useful.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2261697     DOI: 10.1016/0009-8981(90)90271-s

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786