Literature DB >> 22614268

Comparison of screw malposition and vertebral artery injury of C2 pedicle and transarticular screws: meta-analysis and review of the literature.

Robert E Elliott1, Omar Tanweer, Akwasi Boah, Amr Morsi, Tracy Ma, Anthony Frempong-Boadu, Michael L Smith.   

Abstract

STUDY
DESIGN: Literature review and meta-analysis.
OBJECTIVES: To compare the incidence of screw malposition and vertebral artery injury (VAI) with transarticular screws (TAS) and C2 pedicle screws (C2PS) using meta-analysis techniques. SUMMARY OF BACKGROUND DATA: Posterior instrumentation for atlantoaxial fusions can be challenging and risky. Some centers report a higher incidence of VAI with the implantation of TAS compared with C2PS, whereas other data do not support this.
METHODS: Online databases were searched for English language articles between 1994 and April 2011 describing the clinical and radiographic outcomes after insertion of C2PS or TAS. Forty-one studies reporting on 3627 TAS and 33 studies describing 2979 C2PS met inclusion criteria for VAI or clinically significant misplacements (VAI, neurological deficits, or misplacements requiring surgical revision), and 36 studies reporting on 3280 TAS and 28 studies describing 2532 C2PS met inclusion criteria for radiographic misplacement outcomes.
RESULTS: All studies comprised class III evidence. VAI occurred in 26 of 3627 (0.72%) implanted TAS and in 10 of 2979 (0.34%) implanted C2PS (P=0.01). Clinically significant misplacements occurred in 67 TAS (1.84%) and in 10 C2PS (0.34%; P<0.0001). The point estimate of VAI for TAS was 1.68% [confidence interval (CI), 1.23%-2.29%] and was higher than C2PS (1.09%; CI, 0.73%-1.63%; P=0.01). The point estimate of clinically significant screw malposition for TAS was 2.33% (CI, 1.61%-3.37%) and was higher than that of C2PS (1.15%; CI, 0.77%-1.70%; P<0.001).
CONCLUSIONS: With training, experience, and anatomic knowledge, both TAS and C2PS can be inserted accurately and safely. However, improper insertion and VAI can have catastrophic consequences. Our review identified a higher risk of VAI, neurological injury, and clinically significant malpositions with TAS compared with C2PS. These data provide preliminary support for the supposition that C2PS have a lower risk of morbidity.

Entities:  

Mesh:

Year:  2014        PMID: 22614268     DOI: 10.1097/BSD.0b013e31825d5daa

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  10 in total

1.  Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

Authors:  Florian Fensky; Rebecca A Kueny; Kay Sellenschloh; Klaus Püschel; Michael M Morlock; Johannes M Rueger; Wolfgang Lehmann; Gerd Huber; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2013-12-31       Impact factor: 3.134

2.  Potential intraoperative factors of screw-related complications following posterior transarticular C1-C2 fixation: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Anton Kordonskiy; Vladimir Smirnov; Iliya Grigoriev; Ulugbek Khushnazarov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2018-11-22       Impact factor: 3.134

3.  Sudden cerebral infarction after interventional vertebral artery embolism for vertebral artery injury during removal of C1-C2 pedicle screw fixation: a case report.

Authors:  Yi Yang; Hao Liu; Litai Ma; Jiancheng Zeng; Yueming Song; Xiaodong Xie
Journal:  Int J Clin Exp Med       Date:  2015-09-15

4.  Percutaneous atlantoaxial anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion for patients with a high-riding vertebral artery.

Authors:  Ai-Min Wu; Xiang-Yang Wang; Feng Zhou; Xiao-Lei Zhang; Hua-Zi Xu; Yong-Long Chi
Journal:  J Spinal Cord Med       Date:  2016-02-11       Impact factor: 1.985

5.  The radiological feature of anterior occiput-to-axis screw fixation as it guides the screw trajectory on 3D printed models: a feasibility study on 3D images and 3D printed models.

Authors:  Ai-Min Wu; Sheng Wang; Wan-Qing Weng; Zhen-Xuan Shao; Xin-Dong Yang; Jian-Shun Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

6.  Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study.

Authors:  Shuai Guo; Teng Lu; Qiaolong Hu; Baohui Yang; Xijing He; Haopeng Li
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

7.  Gallie technique versus atlantoaxial screw-rod constructs in the treatment of atlantoaxial sagittal instability: a retrospective study of 49 patients.

Authors:  Bo Yuan; Shengyuan Zhou; Xiongsheng Chen; Zhiwei Wang; Weicong Liu; Lianshun Jia
Journal:  J Orthop Surg Res       Date:  2017-07-11       Impact factor: 2.359

8.  Design a novel integrated screw for minimally invasive atlantoaxial anterior transarticular screw fixation: a finite element analysis.

Authors:  Yingkai Zhang; Cheng Li; Lei Li; Yanyan Sun; Zeqing Li; Yunli Mei; Xinyuan Feng
Journal:  J Orthop Surg Res       Date:  2020-07-06       Impact factor: 2.359

9.  Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study.

Authors:  Jacob D Smith; Megan M Jack; Nicholas R Harn; Judson R Bertsch; Paul M Arnold
Journal:  Global Spine J       Date:  2015-09-21

10.  Outcomes of occipitocervical fixation using a spinous process screw in C2 as a third anchor point for occipitocervical fixation: a case presentation.

Authors:  Guanyi Liu; Qing Li; Feng Sheng; Nanjian Xu; Ming Li; Yang Wang; Weihu Ma
Journal:  BMC Musculoskelet Disord       Date:  2020-05-16       Impact factor: 2.362

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.