Seldinger method for intraoperative cholangiography: a practical approach.

N Abbassi-Ghadi1, N Menezes.   

Abstract

Entities:  

Mesh:

Year:  2012        PMID: 22613307      PMCID: PMC3957509          DOI: 10.1308/rcsann.2012.94.4.272a

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.951


× No keyword cloud information.

BACKGROUND

Manipulation of a catheter Into the cystic duct for successful intraoperative cholangiography can be made difficult by the tortuosity of the cystic duct and the spiral valves of Heister. We describe a technique to eliminate these problems and allow successful positioning of the catheter within the cystic duct.

TECHNIQUE

A Steriseal Horner needle (Optech Diagnostic & Surgical, East Melbourne, Australia) Is guided through the abdominal wall and placed adjacent to the incision created In the cystic duct. The cholangiogram catheter Is passed through the needle to protrude through Its laterally placed end opening (Fig 1). This opening angulates the catheter tip, allowing It to be easily negotiated Into the cystic duct.
Figure 1

Position of cholangiogram catheter and needle

Position of cholangiogram catheter and needle If the catheter cannot be manipulated into an adequate position within the duct, a Zebra® straight tip guldewire (0.035ln x 150cm, Boston Scientific, Miami, FL, US) can be fed through the catheter and passed further into the duct. The position of the wire can be checked with an x-ray Image intensifier. The catheter can then be passed over the top of the guldewire In a Seldinger fashion. Once in the correct position, It is secured with a clip, and the guidewlre and Horner needle are removed successively.

DISCUSSION

The advantage of the guidewire is that it readily passes through a tortuous duct or the valves of Heister without difficulty and allows the cholangiogram catheter to slide over it with ease. Ultimately, this Seldinger method should save time, avoiding multiple attempts at manipulating the catheter into the correct position within the cyst duct.
  1 in total

Review 1.  Cystic duct and Heister's "valves".

Authors:  D Dasgupta; M D Stringer
Journal:  Clin Anat       Date:  2005-03       Impact factor: 2.414

  1 in total
  1 in total

1.  Callispheres drug-eluting bead transhepatic artery chemoembolization with oral delivery of sorafenib for the treatment of unresectable liver cancer.

Authors:  Wenhui Wang; Fenqiang Li; Peiying Gan; Baohua Li; Shuangxi Li
Journal:  Front Surg       Date:  2022-09-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.