Literature DB >> 22608820

Assessment for treatment of tripod fractures of the zygoma with microcompressive screws.

Daniel Augusto Gaziri1, Guilherme Omizollo, Giuliano Henrique Miao Luchi, Marília Gerhardt de Oliveira, Cláiton Heitz.   

Abstract

PURPOSE: The present prospective study sought to evaluate a new rigid internal fixation device called a "neck screw," which was applied to patients presenting with a tripod fracture of the zygomaticomaxillary complex. PATIENTS AND METHODS: Seventeen patients with tripod fractures received surgical treatment from 2007 to 2010, and had their zygomaticomaxillary complex monofragments fixed using the neck screw protocol. The adequacy of fracture reduction, stability of the zygomatic monofragment after fixation, cosmetic outcomes, and postoperative complications were used to determine the efficacy of this protocol. The stability provided by the neck screw was evaluated by computed tomography (CT) scans by comparing the immediate postoperative distances between the fractured bone segments (control group) with those distances measured on CT scans obtained 5 weeks later (late group).
RESULTS: The average distance observed between the fractured ends on the immediate postoperative CT scan was less than 0.58 mm, demonstrating adequate fracture reduction. No significant changes were seen in these postoperative values after 5 weeks (Wilcoxon test, P = 1.0000), demonstrating no displacement of the zygomaticomaxillary complex monofragment after fixation using the neck screw.
CONCLUSIONS: The proposed surgical treatment proved efficient in 17 patients. The fixation stability provided by the neck screw was confirmed by subsequent CT scan measurements, statistical analysis, and clinical follow-up during the postoperative period, in which patients showed no significant associated complications, facial asymmetry, enophthalmos, or diplopia.
Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22608820     DOI: 10.1016/j.joms.2012.02.009

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  3 in total

1.  Evaluation of soft tissue asymmetry using cone-beam computed tomography after open reduction and internal fixation of zygomaticomaxillary complex fracture.

Authors:  Dong Hyuck Kim; Rae Hyong Kim; Jun Lee; Young Deok Chee; Kyung Hwan Kwon; Kyoung-Hwan Kwon
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-06-27

2.  Validation of Modified Hertel Exophthalmometer.

Authors:  Rizwana Fathima Jamal; Emmanuel Azariah; Deepak Pandyan; Ravindran Chinnaswami
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-09-11

3.  Etiology, Modalities of Zygomaticomaxillary Complex Fracture, open reduction and fixation.

Authors:  Virendra-Kumar Prajapati; Ajoy-Kumar Shahi; Om Prakash; Subia Ekram
Journal:  J Clin Exp Dent       Date:  2021-03-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.