Literature DB >> 22608432

A highly sensitive electrochemical assay for silver ion detection based on un-labeled C-rich ssDNA probe and controlled assembly of MWCNTs.

Genping Yan1, Yonghong Wang, Xiaoxiao He, Kemin Wang, Jing Su, Zhifeng Chen, Zhihe Qing.   

Abstract

We report here a highly sensitive electrochemical sensing platform for Ag(+) detection based on Ag(+)-induced conformational change of cytosine-rich single stranded DNA C-rich ssDNA probe and the controlled assembly of MWCNTs. In the protocol, the gold electrode was first modified with a dense 16-mercaptohexadecanoic acid self-assembled monolayer (MHA/SAM). The hydrophobic MHA/SAM isolated the electrode from the electroactive indicator in the aqueous solution, which resulted in the electronic transmission blocking. It was eT OFF state. In the presence of Ag(+), C-Ag(+)-C coordination induced the conformational change of C-rich ssDNA probe from random-coil structure to fold into a hairpin structure, which cannot wrap on the surface of the MWCNTs. Then the "naked" MWCNTs can be assembled on the MHA/SAM gold electrode, mediating the electron transfer between the electrode and the electroactive indicator. It generated measurable electrochemical signals (eT ON). The resulting change in electron transfer efficiency was readily measured by differential pulse voltammetry at target Ag(+) concentrations as low as 1.3 nM. The linear response range for Ag(+) detection was from 10 to 500 nM. This method dose not need of electroactive molecules labeling on the C-rich ssDNA probe. Moreover, it has good selectivity to other environmentally relevant metal ions. Therefore, the developed electrochemical assay is an ideal method for Ag(+) detection with some advantages including sensitivity, selectivity, simplicity, low-cost, and no requirement for probe label preparation. We expect that this strategy could be a generalized platform for DNA-based sensing.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22608432     DOI: 10.1016/j.talanta.2012.03.014

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Lateral flow test for visual detection of silver (I) based on cytosine-Ag(I)-cytosine interaction in C-rich oligonucleotides.

Authors:  Zebin Guo; Yafeng Zheng; Hui Xu; Baodong Zheng; Wanwei Qiu; Zebin Guo
Journal:  Mikrochim Acta       Date:  2017-08-24       Impact factor: 5.833

Review 2.  A review on silver-mediated DNA base pairs: methodology and application.

Authors:  Qiao Sun; Xiao Xie; Yujie Song; Litao Sun
Journal:  Biomater Res       Date:  2022-03-07

3.  Complexes of silver(I) ions and silver phosphate nanoparticles with hyaluronic acid and/or chitosan as promising antimicrobial agents for vascular grafts.

Authors:  Dagmar Chudobova; Lukas Nejdl; Jaromir Gumulec; Olga Krystofova; Miguel Angel Merlos Rodrigo; Jindrich Kynicky; Branislav Ruttkay-Nedecky; Pavel Kopel; Petr Babula; Vojtech Adam; Rene Kizek
Journal:  Int J Mol Sci       Date:  2013-06-28       Impact factor: 5.923

4.  Abnormal Anionic Porphyrin Sensing Effect for HER2 Gene Related DNA Detection via Impedance Difference between MWCNTs and Single-Stranded DNA or Double-Stranded DNA.

Authors:  Jingheng Ning; Long Liu; Xin Luo; Min Wang; Donglin Liu; Rong Hou; Donger Chen; Jianhui Wang
Journal:  Molecules       Date:  2018-10-18       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.