Literature DB >> 22607908

Biomechanical effect of rotator cuff augmentation with an acellular dermal matrix graft: a cadaver study.

Hiromichi Omae1, Scott P Steinmann, Chunfeng Zhao, Mark E Zobitz, Prasit Wongtriratanachai, John W Sperling, Kai-Nan An.   

Abstract

BACKGROUND: Acellular human dermal matrix grafts (Graftjacket; Wright Medical Technology, Arlington, TN, USA) are used clinically for rotator cuff augmentation without a detailed understanding of their biomechanical effects. The purpose of this study was to evaluate the effect of augmentation with dermal grafts on the biomechanical effects of rotator cuff repairs.
METHODS: Nine matched pairs of human cadaveric shoulders were used. A single-row rotator cuff repair combined with an augmentation graft was performed on one shoulder, and a single-row repair was performed on the contralateral shoulder as a control. An acellular dermal matrix graft was sutured to the tendon medially and fixed to the humerus laterally. The constructs were preloaded at 10 N and then cyclically loaded between 10 and 180 N for 1000 cycles, followed by tensile testing to failure at 1.0 mm/s.
FINDINGS: The maximum load of the augmentation group (560.2 N, SD 95.5) was greater than that of the control group (345.7 N, SD 60.8), while the linear stiffness of the augmentation group (65.2 N/mm, SD 15.6) was less than that of the control group (77.2 N/mm, SD 15.7). Reliable gap distance data were not obtained during cyclic loading in 5 of 9 augmented repairs due to the elasticity of the dermal matrix graft.
INTERPRETATION: The dermal matrix graft augmentation increased the maximum load but did not increase the linear stiffness. The elasticity of the dermal matrix graft affected the biomechanical effects of the augmented rotator cuff repairs.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22607908     DOI: 10.1016/j.clinbiomech.2012.05.001

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  9 in total

1.  Short-term results of rotator cuff repair using GraftJacket as an interpositional tissue-matched thickness graft.

Authors:  Nikhil Sharma; Ahmed El Refaiy; T F Sibly
Journal:  J Orthop       Date:  2018-05-18

2.  Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs.

Authors:  Chunfeng Zhao; Yasuhiro Ozasa; Haruhiko Shimura; Ramona L Reisdorf; Andrew R Thoreson; Gregory Jay; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Orthop Res       Date:  2015-07-31       Impact factor: 3.494

3.  Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix.

Authors:  Paolo Consigliere; Ioannis Polyzois; Tanaya Sarkhel; Rohit Gupta; Ofer Levy; A Ali Narvani
Journal:  Arch Bone Jt Surg       Date:  2017-01

4.  An augmentation suture technique for arthroscopic rotator cuff repair.

Authors:  Hiromichi Omae; Susumu Yamamoto; Yu Mochizuki; Mitsuo Ochi
Journal:  Arthrosc Tech       Date:  2014-05-05

Review 5.  Biologics for tendon repair.

Authors:  Denitsa Docheva; Sebastian A Müller; Martin Majewski; Christopher H Evans
Journal:  Adv Drug Deliv Rev       Date:  2014-11-21       Impact factor: 15.470

6.  Biomechanical evaluation of a novel double rip-stop technique with medial row knots for rotator cuff repair: an in vitro study.

Authors:  Zhanwen Wang; Hong Li; Zeling Long; Subin Lin; Andrew R Thoreson; Steven L Moran; Anne Gingery; Peter C Amadio; Scott P Steinmann; Chunfeng Zhao
Journal:  Bone Joint Res       Date:  2020-07-23       Impact factor: 5.853

7.  Increased Bite Distance From the Edge Lowers Risk of Pullout of Simple Sutures from Acellular Dermal Allograft.

Authors:  Chad D Hanson; Jay C Thompson; Jake X Checketts; David P Beason; Craig Pille; Lawrence Lemak
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-08-27

8.  Load-deformation characteristics of acellular human scalp: assessing tissue grafts from a material testing perspective.

Authors:  Johann Zwirner; Benjamin Ondruschka; Mario Scholze; Gundula Schulze-Tanzil; Niels Hammer
Journal:  Sci Rep       Date:  2020-11-06       Impact factor: 4.379

9.  Biomechanical Comparison of Augmentation of Engineered Tendon-Fibrocartilage-Bone Composite With Acellular Dermal Graft Using Double Rip-Stop Technique for Canine Rotator Cuff Repair.

Authors:  Zhanwen Wang; Zeling Long; Peter C Amadio; Anne Gingery; Steven L Moran; Scott P Steinmann; Chunfeng Zhao
Journal:  Orthop J Sports Med       Date:  2020-09-02
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.