Literature DB >> 22607851

Rationale and design of the PRAETORIAN trial: a Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy.

Louise R A Olde Nordkamp1, Reinoud E Knops, Gust H Bardy, Yuri Blaauw, Lucas V A Boersma, Johannes S Bos, Peter Paul H M Delnoy, Pascal F H M van Dessel, Antoine H G Driessen, Joris R de Groot, Jean Paul R Herrman, Luc J L M Jordaens, Kirsten M Kooiman, Alexander H Maass, Mathias Meine, Yuka Mizusawa, Sander G Molhoek, Jurjen van Opstal, Jan G P Tijssen, Arthur A M Wilde.   

Abstract

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear. STUDY
DESIGN: The PRAETORIAN trial is an investigator-initiated, randomized, controlled, multicenter, prospective 2-arm trial that outlines the advantages and disadvantages of the subcutaneous ICD. Patients with a class I or IIa indication for ICD therapy without an indication for bradypacing or tachypacing are included. A total of 700 patients are randomized to either the subcutaneous or transvenous ICD (1:1). The study is powered to claim noninferiority of the subcutaneous ICD with respect to the composite primary endpoint of inappropriate shocks and ICD-related complications. After noninferiority is established, statistical analysis is done for potential superiority. Secondary endpoint comparisons of shock efficacy and patient mortality are also made.
CONCLUSION: The PRAETORIAN trial is a randomized trial that aims to gain scientific evidence for the use of the subcutaneous ICD compared with the transvenous ICD in a population of patients with conventional ICD with respect to major ICD-related adverse events. This trial is registered at ClinicalTrials.gov with trial ID NCT01296022.
Copyright © 2012 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22607851     DOI: 10.1016/j.ahj.2012.02.012

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  35 in total

Review 1.  Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.

Authors:  Tien Siang Eric Lim; Boon Yew Tan; Kah Leng Ho; Chuh Yih Paul Lim; Wee Siong Teo; Chi-Keong Ching
Journal:  Singapore Med J       Date:  2015-10       Impact factor: 1.858

2.  The Entirely Subcutaneous Defibrillator - A New Generation and Future Expectations.

Authors:  Hussam Ali; Pierpaolo Lupo; Riccardo Cappato
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08

Review 3.  Current Review of Implantable Cardioverter Defibrillator Use in Patients With Left Ventricular Assist Device.

Authors:  Jacinthe Boulet; Emmanuelle Massie; Blandine Mondésert; Yoan Lamarche; Michel Carrier; Anique Ducharme
Journal:  Curr Heart Fail Rep       Date:  2019-12

Review 4.  Alzheimer's disease: the impact of age-related changes in reproductive hormones.

Authors:  C S Atwood
Journal:  Cell Mol Life Sci       Date:  2005-02       Impact factor: 9.261

Review 5.  Subcutaneous implantable cardiac defibrillators: indications and limitations.

Authors:  Maria Grazia Bongiorni; Stefano Viani; Giulio Zucchelli; Andrea Di Cori; Luca Segreti; Luca Paperini; Dianora Levorato; Adriano Boem; Giulia Branchitta; Diana Andreini; Ezio Soldati
Journal:  Curr Heart Fail Rep       Date:  2015-02

Review 6.  The subcutaneous ICD-current evidence and challenges.

Authors:  Kiran Haresh Kumar Patel; Pier D Lambiase
Journal:  Cardiovasc Diagn Ther       Date:  2014-12

Review 7.  Comparing the safety of subcutaneous versus transvenous ICDs: a meta-analysis.

Authors:  Li Su; Jia Guo; Yingqun Hao; Hong Tan
Journal:  J Interv Card Electrophysiol       Date:  2021-01-11       Impact factor: 1.900

Review 8.  [Leadless pacemakers and subcutaneously implantable cardioverter defibrillators].

Authors:  C Stellbrink; B Hansky; D Meyer Zu Vilsendorf
Journal:  Internist (Berl)       Date:  2018-10       Impact factor: 0.743

Review 9.  [Implantable cardioverter defibrillator].

Authors:  C Stellbrink; D Andresen; D Böcker; T Lewalter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-03

Review 10.  Electrical manipulation of the failing heart.

Authors:  Valerio Zacà; Theodore Murphy; Mauro Biffi
Journal:  Heart Fail Rev       Date:  2018-11       Impact factor: 4.214

View more