OBJECTIVE: This study aimed to evaluate the influence of the casting procedure and cyclic loading of prosthetic frameworks on detorque of prosthetic screws and marginal misfit of single unit implant-supported prostheses.
MATERIALS AND METHODS: Twenty specimens were obtained, each one consisting of a set of an implant (external hexagon 3.75 × 13 mm - Branemark type), a prosthetic abutment (entirely calcinable or overcasted UCLA) and a prosthetic screw. After the specimens were obtained, the prosthetic screws were tightened with 30 Ncm torque and released 24 h later in order to evaluate initial detorque. The screws were retightened and marginal gaps were assessed. All specimens were submitted to 10(6) loading cycles, performed with 2 Hz frequency and 130 N load. The specimens were re-evaluated for marginal misfit and detorque after the mechanical loading (final marginal misfit/final detorque). The results were submitted to analysis of variance for repeated measurements, followed by Tukey HSD test (α = 0.05).
RESULTS: No statistically significant differences were found on detorque values of the prosthetics screws for all groups and intervals evaluated (p = 0.8922). The entirely calcinable abutments showed higher initial marginal misfit compared to the overcasted ones (p = 0.0438). There was no statistically significant difference on marginal misfit before and after mechanical loading for both groups (p > 0.05).
CONCLUSIONS: It can be concluded that the overcasted abutments showed lower misfit values when compared to the entirely casted abutments. No difference was observed on detorque values of prosthetic screws. After mechanical loading there was no difference on marginal misfit and detorque between the groups.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22607236     DOI: 10.3109/00016357.2012.690528

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  1 in total

1.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.