Literature DB >> 22606690

Coupling laser ablation/desorption electrospray ionization to atmospheric pressure drift tube ion mobility spectrometry for the screening of antimalarial drug quality.

Glenn A Harris1, Stephan Graf, Richard Knochenmuss, Facundo M Fernández.   

Abstract

Significant developments in the field of ambient desorption/ionization mass spectrometry (MS) have led to high-throughput direct analysis and imaging capabilities. However, advances in coupling ambient ionization techniques with standalone drift tube ion mobility spectrometry (DTIMS) have been comparatively slower, despite the attractive ruggedness and simplicity of IMS. In this study, we have developed and characterized a laser ablation/desorption electrospray ionization (LADESI) DTIMS platform, and applied it to the detection of active pharmaceutical ingredients (APIs) in antimalarial tablets collected in developing countries. The overarching goal of this work was to perform an initial evaluation of LADESI DTIMS as a technique with the potential for constituting the core of a portable drug quality-testing platform. The set-up consisted of an IR laser for desorption and an electrospray ionizer for capturing the ablated plume coupled to a high-resolution monolithic resistive glass drift tube ion mobility spectrometer. For more confident API identification, tablet extracts were also investigated via electrospray IM MS to correlate LADESI DTIMS reduced mobility (K(0)) values to m/z values. Overall, it was found that the IR LADESI DTIMS platform provided distinct ion mobility spectral fingerprints that could be used to detect the presence of the expected APIs, helping to distinguish counterfeit drugs from their genuine counterparts.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22606690     DOI: 10.1039/c2an35431d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  An effective approach for coupling direct analysis in real time with atmospheric pressure drift tube ion mobility spectrometry.

Authors:  Joel D Keelor; Prabha Dwivedi; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2014-06-06       Impact factor: 3.109

Review 2.  Review on ion mobility spectrometry. Part 1: current instrumentation.

Authors:  R Cumeras; E Figueras; C E Davis; J I Baumbach; I Gràcia
Journal:  Analyst       Date:  2015-03-07       Impact factor: 4.616

3.  Technologies for detecting falsified and substandard drugs in low and middle-income countries.

Authors:  Stephanie Kovacs; Stephen E Hawes; Stephen N Maley; Emily Mosites; Ling Wong; Andy Stergachis
Journal:  PLoS One       Date:  2014-03-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.