Literature DB >> 22596231

Influence of a radiographic contrast media (Iopentol) with different viscosities on capillary perfusion in patients with coronary artery disease.

F Jung1, C Mrowietz, U Gerk, R P Franke.   

Abstract

Radiographic contrast media (RCM) are widely used to visualize blood vessels. Their effects on blood vessels should be minimal so that the object of the measurement - the vessel lumen - is not influenced by the RCM molecules. However, all RCMs exhibit a more or less strong effect on endothelial cells as well as on erythrocytes. These effects are discussed to induce a significant and relevant deceleration of the microcirculation. For some RCMs this could be demonstrated in animal or clinical studies. Therefore, this study investigated the role of the viscosity of a RCM on the mean erythrocyte velocity in nail fold capillaries in patients with coronary artery disease after a bolus injection of the RCM directly into the A. axillaris. Iopentol-350 is a high-viscous Xray contrast medium and induced a short-lasting imbalance of the microcirculation already in vascular regions not affected by atherosclerosis. This effect was - in the early phase after injection - significantly stronger than after application of the low viscous Iopentol-150. In patients with severe coronary artery disease and a myocardial perfusion at its limits, the injection of high-viscous X-ray contrast media could induce massive perturbations in the microcirculation and even ischemia. As a consequence a further impairment of both systolic and diastolic functions may occur.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22596231     DOI: 10.3233/CH-2012-1557

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  2 in total

1.  Contrast-induced Hyperemia as an Alternative to Drug-induced Hyperemia in the Evaluation of the Fractional Flow Reserve in Coronary Lesions.

Authors:  Nobuo Shiode; Tomokazu Okimoto; Hiromichi Tamekiyo; Tomoharu Kawase; Kenichi Yamane; Yuzo Kagawa; Yuto Fujii; Yusuke Ueda; Naoya Hironobe; Yasuko Kato; Yasuhiko Hayashi
Journal:  Intern Med       Date:  2017-02-01       Impact factor: 1.271

Review 2.  Effects of radiographic contrast media on the micromorphology of the junctional complex of erythrocytes visualized by immunocytology.

Authors:  Ralf-Peter Franke; Anne Krüger; Tim Scharnweber; Folker Wenzel; Friedrich Jung
Journal:  Int J Mol Sci       Date:  2014-09-12       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.