Literature DB >> 2259557

Pulmonary function following positive pressure ventilation initiated immediately after birth in infants with respiratory distress syndrome.

C Bose1, B Wood, G Bose, D Donlon, M Friedman.   

Abstract

Cardiopulmonary function following positive pressure ventilation, initiated immediately after birth, was evaluated in 10 very low birthweight infants with respiratory distress syndrome (RDS; RDS infants). Multiple gas rebreathing methodology was used to measure functional residual capacity (FRC), diffusing capacity of the lung for carbon monoxide (DLCO) and effective pulmonary capillary blood flow (Qeff) at 2, 24, and 72 hr of age. Cardiopulmonary function variables were also measured at 2 hr of age in 10 infants of similar birthweight who did not have RDS (non-RDS infants). In RDS infants, mean FRC at both 2 hr of age (15 mL/kg or 0.42 mL/cm) and 24 hours of age (20 mL/kg or 0.54 mL/cm) was less than published predicted values for healthy infants and significantly less than values in non-RDS infants at 2 hours of age (29 mL/kg or 0.8 mL/cm). By 72 hr of age, mean FRC in RDS infants rose to predicted. At 2 and 24 hours of age, mean Qeff in RDS infants (41 and 38 mL/min/kg, respectively) was below predicted, as well as below the value observed in non-RDS infants at 2 hr of age (62 mL/min/kg). in RDS infants. DLCO remained well below published predicted values throughout the first three days of life. We conclude that early aggressive respiratory therapy does not result in the establishment of normal lung volumes during the first day of life, but it does so by 3 days of age. However, in spite of intubation immediately after birth and the application of continuous positive pressure ventilation during the first 3 days of life, very low birthweight infants with RDS continue to have significant alteration in lung function, evidenced by impaired diffusing capacity of the lung and low arterial-alveolar oxygen tension ratios.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2259557     DOI: 10.1002/ppul.1950090410

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  2 in total

1.  Lung volume and pulmonary blood flow measurements following exogenous surfactant.

Authors:  J Alexander; A D Milner
Journal:  Eur J Pediatr       Date:  1995-05       Impact factor: 3.183

2.  Measurement of lung volume and optimal oxygenation during high frequency oscillation.

Authors:  G Dimitriou; A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-05       Impact factor: 5.747

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.