Literature DB >> 22594355

Combination of copeptin and troponin assays to rapidly rule out non-ST elevation myocardial infarction in the emergency department.

Sandrine Charpentier1, Françoise Maupas-Schwalm, Maxime Cournot, Meyer Elbaz, Jean Marie Botella, Dominique Lauque.   

Abstract

OBJECTIVES: The aim of this study was to analyze the diagnostic accuracy and the clinical usefulness of the combination of troponin I (cTnI) and copeptin measured at presentation with an automated assay to rapidly rule out non-ST elevation myocardial infarction (NSTEMI) in patients with suspected cardiac chest pain presenting to an emergency department (ED).
METHODS: This study was an ancillary analysis of a prospective observational study. Copeptin and cTnI levels were sampled at presentation in 641 consecutive patients admitted to the ED for chest pain with onset within the last 12 hours and without ST elevation on a 12-lead electrocardiogram (ECG). Copeptin was measured with an automated assay and troponin with conventional assay. The performance of a combination of cTnI and copeptin for NSTEMI diagnosis was studied, the clinical utility was assessed by multivariate analysis, and an area under the curve (AUC) calculation was used to determine accuracy.
RESULTS: NSTEMI was diagnosed in 95 patients (15%). The sensitivity and negative predictive value (NPV) of the combination of copeptin and cTnI measures were 90.4% (95% confidence interval [CI] = 88.2% to 92.7%) and 97.6% (95% CI = 96.4% to 98.7%) versus 55.3% (95% CI = 51.5% to 59.2%) and 92.8% (95% CI = 90.8% to 94.8%) with cTnI alone. The AUC of the combination of copeptin and cTnI was 0.89 (95% CI = 0.85% to 0.92%) and was significantly higher than the AUC of cTnI alone (0.77, 95% CI = 0.72% to 0.82%, p < 0.05). The patient classification was slightly improved when copeptin was added to the usual diagnostic tools used for NSTEMI management.
CONCLUSIONS: In this study, determination of copeptin, in addition to cTnI, improves early diagnostic accuracy of NSTEMI. However, the sensitivity of this combination even using a conventional troponin assay remains insufficient to safely rule out NSTEMI at the time of presentation.
© 2012 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22594355     DOI: 10.1111/j.1553-2712.2012.01350.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  10 in total

1.  Prognostic value of copeptin in patients with acute myocardial infarction treated with percutaneous coronary intervention: a prospective cohort study.

Authors:  Marta Roczek-Janowska; Michal Kacprzak; Malgorzata Dzieciol; Marzenna Zielinska; Krzysztof Chizynski
Journal:  J Thorac Dis       Date:  2021-07       Impact factor: 2.895

Review 2.  Copeptin as a Diagnostic and Prognostic Biomarker in Cardiovascular Diseases.

Authors:  Danni Mu; Jin Cheng; Ling Qiu; Xinqi Cheng
Journal:  Front Cardiovasc Med       Date:  2022-07-04

3.  Renal function interferes with copeptin in prediction of major adverse cardiac events in patients undergoing vascular surgery.

Authors:  Claudia Schrimpf; Hans-Joerg Gillmann; Bianca Sahlmann; Antje Meinders; Jan Larmann; Mathias Wilhelmi; Thomas Aper; Saad Rustum; Ralf Lichtinghagen; Gregor Theilmeier; Omke E Teebken
Journal:  PLoS One       Date:  2015-04-13       Impact factor: 3.240

Review 4.  Copeptin-marker of acute myocardial infarction.

Authors:  Martin Möckel; Julia Searle
Journal:  Curr Atheroscler Rep       Date:  2014-07       Impact factor: 5.113

5.  Diagnostic accuracy of adding copeptin to cardiac troponin for non-ST-elevation myocardial infarction: A systematic review and meta-analysis.

Authors:  Hyungoo Shin; Bo-Hyoung Jang; Tae Ho Lim; Juncheol Lee; Wonhee Kim; Youngsuk Cho; Chiwon Ahn; Kyu-Sun Choi
Journal:  PLoS One       Date:  2018-07-06       Impact factor: 3.240

6.  Clinical role of serum Copeptin in acute coronary syndrome.

Authors:  Manal Abd El Baky Mahmoud; Menat Allah Ali Shaaban; Ali Ali Ramzy
Journal:  Egypt Heart J       Date:  2018-05-10

7.  Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction.

Authors:  Kyung Su Kim; Gil Joon Suh; Sang Hoon Song; Yoon Sun Jung; Taegyun Kim; So Mi Shin; Min Woo Kang; Min Sung Lee
Journal:  Clin Exp Emerg Med       Date:  2020-03-31

8.  The combination of high sensitivity troponin T and copeptin facilitates early rule-out of ACS: a prospective observational study.

Authors:  Johan Thelin; Catharina Borna; David Erlinge; Bertil Öhlin
Journal:  BMC Cardiovasc Disord       Date:  2013-06-18       Impact factor: 2.298

9.  Diagnostic accuracy of copeptin sensitivity and specificity in patients with suspected non-ST-elevation myocardial infarction with troponin I below the 99th centile at presentation.

Authors:  Jonathan Duchenne; Stéphanie Mestres; Nicolas Dublanchet; Nicolas Combaret; Geoffroy Marceau; Laurent Caumon; Laurent Dutoit; Sylvie Ughetto; Pascal Motreff; Vincent Sapin; Jeannot Schmidt
Journal:  BMJ Open       Date:  2014-03-24       Impact factor: 2.692

Review 10.  Performance of Copeptin for Early Diagnosis of Acute Coronary Syndromes: A Systematic Review and Meta-Analysis of 14,139 Patients.

Authors:  Lukasz Szarpak; Marcin Lapinski; Aleksandra Gasecka; Michal Pruc; Wiktoria L Drela; Mariusz Koda; Andrea Denegri; Frank W Peacock; Miłosz J Jaguszewski; Krzysztof J Filipiak
Journal:  J Cardiovasc Dev Dis       Date:  2021-12-27
  10 in total