Literature DB >> 22592122

Arthroscopic mosaicplasty for osteochondral lesions of the knee: computer-assisted navigation versus freehand technique.

Paolo Di Benedetto1, Mustafa Citak, Daniel Kendoff, Padhraig F O'Loughlin, Eduardo M Suero, Andrew D Pearle, Dimitrios Koulalis.   

Abstract

PURPOSE: The purpose of this study was to compare a freehand arthroscopic approach versus mosaicplasty for treatment of osteochondral lesions of the knee with a navigated arthroscopic technique.
METHODS: Four whole cadaveric lower limbs were used. A conventional navigation system was used in combination with an autologous osteochondral graft transplantation system (Osteochondral Autograft Transfer System [OATS]; Arthrex, Naples, FL). The congruity of the articular surface was measured with the navigation probe to detect any difference between the surface created by the grafts and the surface of the femoral condyle surrounding them. The angle relates to a line perpendicular to the articular surface. This line is made by the cutting instrument for graft harvesting and insertion and the articular surface.
RESULTS: The mean angle of graft harvest was 3.4° (range, 0° to 10°) in the navigated group versus 14.8° (range, 6° to 26°) in the freehand group (P < .0003). The mean angle for recipient-site coring was 1.5° (range, 0° to 5°) in the navigated group versus 12.6° (range, 4° to 17°) in the freehand group (P < .0003). The mean angle of graft placement was 2° (range, 1° to 5°) in the navigated group versus 10.8° (range, 5° to 15°) in the freehand group (P = .0002). The mean protrusion height of the plug was 0.23 mm (range, 0.1 to 0.5 mm; SD, 0.16) in the navigated group versus 0.34 mm (range, 0.0 to 0.7 mm; SD, 0.25) in the freehand group (P = .336).
CONCLUSIONS: Computer-assisted arthroscopic mosaicplasty for treatment of osteochondral lesions in the cadaveric model presented in this study allows permanent visualization of the angle of recipient-site preparation, the depth of the donor plug and the recipient plug, and the angle of insertion of the graft at the recipient site. CLINICAL RELEVANCE: This study shows evidence of potentially greater precision and reproducibility of navigated arthroscopic mosaicplasty when compared with an arthroscopic freehand technique in a cadaveric model. However, true clinical outcome benefit will only be elucidated upon performance of appropriate clinical studies.
Copyright © 2012 Arthroscopy Association of North America. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22592122     DOI: 10.1016/j.arthro.2012.02.013

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  2 in total

1.  Applications of computer navigation in sports medicine knee surgery: an evidence-based review.

Authors:  Simon W Young; Marc R Safran; Mark Clatworthy
Journal:  Curr Rev Musculoskelet Med       Date:  2013-06

2.  Image-guided techniques improve accuracy of mosaic arthroplasty.

Authors:  Stephen Sebastyan; Manuela Kunz; A James Stewart; Davide D Bardana
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-07-07       Impact factor: 2.924

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.