Zone 2 flexor digitorum profundus and superficialis rupture treated with single-stage tendon reconstruction using an Active Hunter Rod Implant.

Jonathan B Macknin1, Kevin J Malone.   

Abstract

To our knowledge, no report has been published of a flexor tendon rupture as a result of a closed phalangeal fracture.A 58-year-old woman with multiple medical comorbidities presented with a closed, apex volar fracture of her long finger proximal phalynx with clinically intact flexor digitorum profundus and superficialis tendons in zone 2 of the flexor tendon sheath. After 5 weeks of nonoperative treatment, the patient reported hearing a pop in her finger, and clinical findings suggested rupture of the flexor digitorum profundus and superficialis tendons. Intraoperatively, the nonreparable attritional rupture was underneath the A2 pulley. A bony prominence in the tendon sheath floor from the healed phalynx fracture made rerupture a concern with a tendon graft. A Hunter Active Tendon Implant (Wright Medical Technology, Inc, Arlington, Tennessee) was used to reconstruct the flexor digitorum profundus tendon to avoid a second procedure. The patient progressed well and had regained a functional arc of active finger range of motion by 2 months postoperatively.The Hunter Active Tendon Implant provided a suitable alternative to a 2-staged procedure, with the added benefit that a good tendon bed was developed in the event that a second procedure was needed. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22588423     DOI: 10.3928/01477447-20120426-36

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  1 in total

1.  Complex reconstruction of the dorsal hand using the induced membrane technique associated with bone substitute: A case report.

Authors:  Vivien Moris; David Guillier; Philippe Rizzi; Alice De Taddeo; Benoit Henault; Alain Tchurukdichian; Narcisse Zwetyenga
Journal:  JPRAS Open       Date:  2015-12
  1 in total