Literature DB >> 22586044

Absolute neutrophil counts from automated hematology instruments are accurate and precise even at very low levels.

Erik K Amundsen1, Petter Urdal, Tor-Arne Hagve, Mette R Holthe, Carola E Henriksson.   

Abstract

Using 106 samples from patients with an absolute neutrophil count (ANC) less than 2.0 × 10(9)/L, two 5-part differential hematology instruments (Sysmex XE-2100, Sysmex, Kobe, Japan, and Advia 2120i, Siemens Healthcare Diagnostics, Deerfield, IL), two 3-part differential hematology instruments (Sysmex K4500, Sysmex, and Advia 60, Siemens Healthcare Diagnostics), and an automated system for examination of microscopic slides (CellaVision DM96, CellaVision, Lund, Sweden) were compared with a flow cytometric (FCM) neutrophil count using monoclonal antibodies for cell classification. The precision and accuracy of the 5-part differential instrument ANC was very good at more than 0.1 × 10(9)/L, although a small systematic difference (10.3%) was found between the 2 instruments. The ANC of the 3-part differential instruments was less reliable, but the WBC count correlated very well with the WBC count from the 5-part differential instruments. Also, the neutrophil count from the CellaVision DM96 compared very well with FCM. When used in the correct laboratory setting, all of the evaluated instruments provide ANCs and WBCs with adequate accuracy and precision.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22586044     DOI: 10.1309/AJCPOJN03GOXZRZY

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Choosing wisely during the COVID-19 pandemic: optimising outpatient cancer care while conserving resources with a new algorithm to report automated ANC results.

Authors:  Maly Fenelus; Tamiqua Graham; Ryan Golden; Jessica L Bautista; Rachel J So; Nora Plante; Ellinor I B Peerschke
Journal:  J Clin Pathol       Date:  2020-11-16       Impact factor: 3.411

Review 2.  "Blasts" in myeloid neoplasms - how do we define blasts and how do we incorporate them into diagnostic schema moving forward?

Authors:  Xueyan Chen; Jonathan R Fromm; Kikkeri N Naresh
Journal:  Leukemia       Date:  2022-01-19       Impact factor: 11.528

3.  Accuracy of the CellaVision DM96 platform for reticulocyte counting.

Authors:  Etienne R Mahe; Diane Higa; Christopher Naugler; Adnan Mansoor; Meer-Taher Shabani-Rad
Journal:  J Pathol Inform       Date:  2014-05-26

4.  Prediction of leukocyte counts during paediatric acute lymphoblastic leukaemia maintenance therapy.

Authors:  Santeri Karppinen; Olli Lohi; Matti Vihola
Journal:  Sci Rep       Date:  2019-12-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.