[Percutaneous vertebroplasty for pain relief in patients with osteoporotic spine fractures].

Rawdha Tekaya1, Sourour Yaich, Hatem Rajhi, Ines Naccache, Rafik Zouari.   

Abstract

BACKGROUND: Percutaneous vertebroplasty (PVP) is an interventional radiology technique where pathological vertebral bodies are filled with acrylic cement. This method is used to strengthen the vertebral body and reduce pain in certain diseases involving the vertebrae such as osteoporosis. AIM: To evaluated PVP in symptomatic osteoporotic vertebral fractures after failure of conservative management.
METHODS: Between November 2008 to December 2009, PVP was performed for osteoporotic vertebral fractures i 12 consecutive patients in a single institution. Medium term (3 days and 15 days post PVP) and long term follow up (1 month and 3 months post PVP) consisted in the evaluation of residual or secondary pain using Huskisson's visual analogue scale.
RESULTS: A total of 20 vertebrae were treated. Mean follow up was 80 days (30-90 days). Significant symptomatic improvement (p=0.002) was noted with pre PVP pain score of 7.4 (±1.6 ), 3 days post PVP score of 4.1 (±2.1), 15 days post PVP score of 1.8 (±1.1), 1 month post PVP score of 1.22 (±1.06) and 3 months post score of 1.4 (±1.14).
CONCLUSION: PVP appears to be an effective technique in the treatment of symptomatic osteoporotic vertebral fractures with approximately 94% of satisfactory results in the short and medium term period.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22585643

Source DB:  PubMed          Journal:  Tunis Med        ISSN: 0041-4131


  2 in total

1.  Clinical efficacy of zoledronic acid combined with percutaneous kyphoplasty in the prevention and treatment of osteoporotic vertebral compression fracture: A systematic review and meta-analysis.

Authors:  Kaiming Li; Hao Gong; Rui Xie; Jinyu Gu; Shangquan Wang; Chengyu Lin; Jing Yin; Xiaozhou Hou; Qing Zhang; Linghui Li; Yanke Hao
Journal:  Medicine (Baltimore)       Date:  2021-04-02       Impact factor: 1.817

2.  Clinical application of the pedicle in vitro restorer in percutaneous kyphoplasty.

Authors:  Yimin Qi; Yiwen Zeng; Dalin Wang; Jisheng Sui; Qiang Wang
Journal:  J Orthop Surg Res       Date:  2018-10-25       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.