Literature DB >> 22583587

An in-vitro assessment of weekly cumulative fluoride release from three glass ionomer cements used for orthodontic banding.

Elaheh Vahid-Dastjerdi1, Ali Borzabadi-Farahani, Homa Pourmofidi-Neistanak, Nazila Amini.   

Abstract

OBJECTIVES: To compare the in-vitro Weekly Cumulative Fluoride Release (WCFR) of three Glass Ionomer Cements (GICs) used for orthodontic banding.
MATERIALS AND METHODS: The GICs tested were Granitec (Confi-Dental, Louisville, CO, USA), Bandtite (American Orthodontics, Sheboygan, WI, USA) and Ariadent (Apadana Tak Co, Tehran, Iran). Fifteen discs of each GIC were constructed (6mm diameter and 1.5mm depth). Specimens were immersed in 5 ml of deionised water and the WCFR was measured at weekly intervals, on days 1, 8, 15, 22 and 29 after immersion in deonised water, using the potentiometery device and single junction saturated calomel electrode technique (Jenway, England, UK). To compare the WCFR profile of 3 GICS, data were subjected to the one-way analysis of variance (ANOVA), and were appropriate, the Scheffe or Tamhane multiple comparison tests (post-hoc). For assessing the longitudinal changes of average WCFRs in 3 GICs, the repeated measures ANOVA were used. Post hoc tests using the Bonferroni correction was also used to compare the average WCFRs at different time-points.
RESULTS: One-way ANOVA and post-hoc multiple comparison tests revealed significant differences in WCFR among 3 GICs at five time-points (p<0.05). The post-hoc multiple comparison test revealed Bandtite cement had consistently higher WCFR at all time-points, compared to Granitec and Ariadent cements (p<0.05). The one-way ANOVA test revealed significant differences in WCFR at different time-points for all GIC groups (p<0.05). The day 8 exhibited the highest WCFR for all GICs. The repeated measures ANOVA test revealed significant differences in WCFR at different time-points for all GIC groups (p<0.0005). Reviewing average WCFR on days 22 and 29, these values for Granitec, Bandtite and Ariadent GICs, were higher (p<0.05), not different (p>0.05), and significantly lower (p<0.05) than the day 1 values, respectively.
CONCLUSIONS: Bandtite followed by Granitec showed higher WCFR compared to Ariadent.
Copyright © 2011 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22583587     DOI: 10.1016/j.pio.2011.09.002

Source DB:  PubMed          Journal:  Prog Orthod        ISSN: 1723-7785            Impact factor:   2.750


  6 in total

1.  Orthodontic bracket designs and their impact on microbial profile and periodontal disease: A clinical trial.

Authors:  Nikesh N Moolya; Arvind Shetty; Neha Gupta; Anvesha Gupta; Vivek Jalan; Rashmi Sharma
Journal:  J Orthod Sci       Date:  2014-10

2.  Preliminary In Vitro Study of Fluoride Release from Selected Ormocer Materials.

Authors:  Piotr Kosior; Maciej Dobrzynski; Aneta Zakrzewska; Lukasz Grosman; Mariusz Korczynski; Tomasz Blicharski; Martina Gutbier; Adam Watras; Rafal J Wiglusz
Journal:  Materials (Basel)       Date:  2021-04-27       Impact factor: 3.623

Review 3.  Iatrogenic possibilities of orthodontic treatment and modalities of prevention.

Authors:  Nazeer Ahmed Meeran
Journal:  J Orthod Sci       Date:  2013-07

4.  A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives.

Authors:  Sudhir Sharma; Pradeep Tandon; Amit Nagar; Gyan P Singh; Alka Singh; Vinay K Chugh
Journal:  J Orthod Sci       Date:  2014-04

5.  Covering of fiber-reinforced composite bars by adhesive materials, is it necessary to improve the bond strength of lingual retainers?

Authors:  Farzin Heravi; Navid Kerayechian; Saied Mostafa Moazzami; Hooman Shafaee; Parya Heravi
Journal:  J Orthod Sci       Date:  2015 Oct-Dec

Review 6.  Prevention and Treatment of White Spot Lesions in Orthodontic Patients.

Authors:  Maryam Khoroushi; Marzie Kachuie
Journal:  Contemp Clin Dent       Date:  2017 Jan-Mar
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.