Literature DB >> 22582798

Effects of focused ion beam milling on electron backscatter diffraction patterns in strontium titanate and stabilized zirconia.

N Saowadee1, K Agersted, J R Bowen.   

Abstract

This study investigates the effect of focused ion beam (FIB) current and accelerating voltage on electron backscatter diffraction pattern quality of yttria-stabilized zirconia (YSZ) and Nb-doped strontium titanate (STN) to optimize data quality and acquisition time for 3D-EBSD experiments by FIB serial sectioning. Band contrast and band slope were used to describe the pattern quality. The FIB probe currents investigated ranged from 100 to 5000 pA and the accelerating voltage was either 30 or 5 kV. The results show that 30 kV FIB milling induced a significant reduction of the pattern quality of STN samples compared to a mechanically polished surface but yielded a high pattern quality on YSZ. The difference between STN and YSZ pattern quality is thought to be caused by difference in the degree of ion damage as their backscatter coefficients and ion penetration depths are virtually identical. Reducing the FIB probe current from 5000 to 100 pA improved the pattern quality by 20% for STN but only showed a marginal improvement for YSZ. On STN, a conductive coating can help to improve the pattern quality and 5 kV polishing can lead to a 100% improvement of the pattern quality relatively to 30 kV FIB milling. For 3D-EBSD experiments of a material such as STN, it is recommended to combine a high kV FIB milling and low kV polishing for each slice in order to optimize the data quality and acquisition time.
© 2012 The Authors Journal of Microscopy © 2012 Wadsworth Center, New York State Department of Health.

Entities:  

Year:  2012        PMID: 22582798     DOI: 10.1111/j.1365-2818.2012.03616.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  2 in total

1.  On the bulk degradation of yttria-stabilized nanocrystalline zirconia dental implant abutments: an electron backscatter diffraction study.

Authors:  V Ocelík; U Schepke; H Haji Rasoul; M S Cune; J Th M De Hosson
Journal:  J Mater Sci Mater Med       Date:  2017-07-06       Impact factor: 3.896

2.  Polynomial fitting method of background correction for electron backscatter diffraction patterns.

Authors:  Yi-Yun Tsai; Yi-Chen Pan; Jui-Chao Kuo
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.