Complementary use of video-electroencephalography and magnetoencephalography in frontal lobe epilepsy.

Xin-Tong Wu1, Stefan Rampp, Rüdiger Hopfengärtner, Michael Buchfelder, Dong Zhou, Hermann Stefan.   

Abstract

PURPOSE: The aim of this study was to compare magnetoencephalography (MEG) and video-electroencephalography (VEEG) source localization in frontal lobe epilepsy (FLE) and determine if these methods can be complementary to each other in clinical practice.
METHOD: Thirty patients with pharmaco-resistant FLE who underwent epilepsy surgery were retrospectively enrolled. Video EEG was recorded using an IT-med system using 10/20 system. Regional localization of spikes in VEEG was defined as spikes discharged from adjacent electrodes and no further propagation to a large and/or contralateral area. Magnetoencephalography was recorded for the purpose of focus assessment. Magnetoencephalography spikes were detected for dipole localization of the epileptogenic cortex and the epileptogenic area was classified as mono- or multi-focal.
RESULTS: Regional spike discharges were identified in the interictal VEEG of 20 patients and in the ictal VEEG of 17 patients. Thirteen patients had regional spikes in both interictal and ictal VEEG. Mono-focal localization was identified in the MEG of 20 patients. Fourteen of these patients had regional spike discharges in VEEG. In the remaining six patients, sources localization was only identified by MEG and there were no regional spike discharges either interictal or ictal VEEG.
CONCLUSION: In clinical practice, VEEG is the routine procedure in the presurgical evaluation of FLE. However, we found six cases in which VEEG failed to locate the epileptogenic area that was identified by MEG. We therefore propose that combining VEEG and MEG will optimize the noninvasive presurgical evaluation of epileptiform activities in FLE.
Copyright © 2012 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22578278     DOI: 10.1016/j.seizure.2012.04.007

Source DB:  PubMed          Journal:  Seizure        ISSN: 1059-1311            Impact factor:   3.184


  1 in total

1.  Accuracy of Interictal and Ictal Electric and Magnetic Source Imaging: A Systematic Review and Meta-Analysis.

Authors:  Praveen Sharma; Margitta Seeck; Sándor Beniczky
Journal:  Front Neurol       Date:  2019-12-03       Impact factor: 4.003

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.