Literature DB >> 22578180

Dark-light change of iris parameters and related factors among American Caucasians, American Chinese, and Mainland Chinese.

Dandan Wang1, Mingguang He, Lingling Wu, Andrew Kao, Melike Pekmezci, Kuldev Singh, Shan Lin.   

Abstract

PURPOSE: To assess the distribution of dark-light changes in iris features and associated factors amongst American Caucasians, American Chinese and mainland Chinese aged 40 years and over.
METHODS: Four gender- and age-matched cohorts: Caucasians, American Chinese, Southern Chinese and Northern Chinese comprised the study population. Anterior segment optical coherence tomography (ASOCT) images were acquired under dark and light conditions. Customized software was used to calculate iris thickness at 750 μm from the scleral spur (IT750), iris curvature (ICurv), iris area (IArea), and pupil diameter (PD) from ASOCT images.
RESULTS: Data from 121, 124, 121 and 120 subjects were available for American Caucasian, American Chinese, Southern and Northern Chinese subjects respectively. Caucasians had significantly less dark-light change (Δ) of IT750 and greater ΔPD than Chinese. When using multiple linear regression analyses, the inter-ethnic difference for ΔIT750 was independent of age, gender, refractive error, anterior chamber width and axial length. After controlling for ΔPD, ΔICurv was found to be inversely associated with age (β = -0.001, P = 0.001). Independent predictors of greater ΔPD included younger age (β = -0.02, P = 0.001), Caucasian ethnicity (β = -0.022, P = 0.009) and wider anterior chamber (β = 0.18, P = 0.03).
CONCLUSIONS: Compared with Caucasians, Chinese irides show greater thickening with light to dark adaptation despite the lesser change of PD in Chinese. The change of iris area per unit change of pupil diameter from dark to light did not differ between ethnicities. These dynamic characteristics intrinsic to Chinese irides may partially account for the substantially increased risk for angle closure among this ethnic group.

Entities:  

Mesh:

Year:  2012        PMID: 22578180     DOI: 10.3109/02713683.2012.660593

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  7 in total

1.  Comparison of iris insertion classification among american caucasian and ethnic Chinese using ultrasound biomicroscopy.

Authors:  Ye Elaine Wang; Yingjie Li; Dandan Wang; Mingguang He; Lingling Wu; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-03       Impact factor: 4.799

2.  The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

Authors:  Sakari Nakamine; Hiroshi Sakai; Yoshikuni Arakaki; Michiko Yonahara; Tadayoshi Kaiya
Journal:  Jpn J Ophthalmol       Date:  2017-11-01       Impact factor: 2.447

3.  Association of Angle Width With Progression of Normal-Tension Glaucoma: A Minimum 7-Year Follow-up Study.

Authors:  Ahnul Ha; Young Kook Kim; Jin Wook Jeoung; Dong Myung Kim; Ki Ho Park
Journal:  JAMA Ophthalmol       Date:  2019-01-01       Impact factor: 7.389

4.  The Reliability, Validity, and Normative Data of Interpupillary Distance and Pupil Diameter Using Eye-Tracking Technology.

Authors:  Nicholas P Murray; Melissa Hunfalvay; Takumi Bolte
Journal:  Transl Vis Sci Technol       Date:  2017-07-03       Impact factor: 3.283

5.  Anterior Segment Parameters of Filipino-Americans Compared to Chinese-Americans and Caucasian Americans Using Anterior Segment Optical Coherence Tomography.

Authors:  Christine S Siguan-Bell; Sunee Chansangpetch; Claudio I Perez; Anne Kutzscher; Dandan Wang; Mingguang He; Catherine Oldenburg; Michael R Hee; Shan C Lin
Journal:  Transl Vis Sci Technol       Date:  2019-04-04       Impact factor: 3.283

6.  Reliability of Ocular Aberration Measurements in Children with Moderate and Low Myopia under Scotopic Conditions.

Authors:  Zhouyue Li; Dongmei Cui; Sichun Ao; Weizhong Lan; Xiao Yang
Journal:  J Ophthalmol       Date:  2018-02-11       Impact factor: 1.909

7.  Intraocular pressure change during reading or writing on smartphone.

Authors:  Ahnul Ha; Young Kook Kim; Young Joo Park; Jin Wook Jeoung; Ki Ho Park
Journal:  PLoS One       Date:  2018-10-25       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.