Literature DB >> 22576427

Respiratory inductive plethysmography: a comparative study between isovolume maneuver calibration and qualitative diagnostic calibration in healthy volunteers assessed in different positions.

Renata Cléia Claudino Barbosa1, Celso Ricardo Fernandes de Carvalho, Henrique Takachi Moriya.   

Abstract

OBJECTIVE: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions.
METHODS: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 ± 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots.
RESULTS: The values of the constant of proportionality (K) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 ± 0.5 vs. 2.0 ± 1.2, in the supine position, 2.5 ± 0.8 vs. 0.6 ± 0.3 in the sitting position, and 2.0 ± 0.8 vs. 0.6 ± 0.3 in the orthostatic position (p < 0.05 for all).
CONCLUSIONS: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Entities:  

Mesh:

Year:  2012        PMID: 22576427     DOI: 10.1590/s1806-37132012000200008

Source DB:  PubMed          Journal:  J Bras Pneumol        ISSN: 1806-3713            Impact factor:   2.624


  5 in total

1.  Non-invasive respiratory monitoring using long-period fiber grating sensors.

Authors:  M D Petrović; J Petrovic; A Daničić; M Vukčević; B Bojović; Lj Hadžievski; T Allsop; G Lloyd; D J Webb
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

2.  Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model.

Authors:  Robinder G Khemani; Rutger Flink; Justin Hotz; Patrick A Ross; Anoopindar Ghuman; Christopher J L Newth
Journal:  Pediatr Res       Date:  2014-10-03       Impact factor: 3.756

3.  INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS.

Authors:  Juliana Vieira Campos; Mariana Alves Moreno; Ricardo de Bastos Silva; Jessica Neves Quirino da Silva; Milena Ferreira de Carvalho; Rayssa Christina Abreu Dos Santos; Rodrigo Tosta Peres; Rosana da Silva Santos; Halina Cidrini Ferreira
Journal:  Rev Paul Pediatr       Date:  2020-12-07

4.  Changes in breathing while listening to read speech: the effect of reader and speech mode.

Authors:  Amélie Rochet-Capellan; Susanne Fuchs
Journal:  Front Psychol       Date:  2013-12-09

5.  Publications in the Brazilian Journal of Pulmonology.

Authors:  Carlos Roberto Ribeiro Carvalho
Journal:  J Bras Pneumol       Date:  2013 Jan-Feb       Impact factor: 2.624

  5 in total