Literature DB >> 22575575

Development of a rapid and specific loop-mediated isothermal amplification detection method that targets Marek's disease virus meq gene.

Xiuying Wei1, Xingming Shi, Yan Zhao, Jing Zhang, Mei Wang, Changjun Liu, Hongyu Cui, Shunlei Hu, Yanming Quan, Hongyan Chen, Yunfeng Wang.   

Abstract

A rapid, sensitive and specific loop-mediated isothermal amplification (LAMP) method was developed and evaluated for the detection of Marek's disease virus (MDV) by amplification of conserved MDV meq gene sequences. LAMP is an innovative technique that allows the rapid detection of targeted nucleic acid sequences under isothermal conditions without the need for complex instrumentation. In this study, meq gene sequences were amplified successfully from different MDV strains by LAMP within 60min and no cross-reactivity was observed in a panel of related viruses that were associated with diseases of chickens. The detection limit of LAMP was 3.2 copies/million cells compared with 320 copies/million cells required for conventional PCR. Positive detection rates were assessed using either LAMP or PCR by examination of feather follicles that were collected from chickens infected experimentally with either strain J-1 (n=20) or strain Md5 (n=17), In addition to these samples, three isolates that were suspected to have been infected in the clinic were also tested. Results showed that the positive detection rate for LAMP was 95% (38/40), compared with 87.5% (35/40) and 90% (38/40) for strains J-1 and Md5 by PCR, respectively. These results indicated that the LAMP assay was more sensitive, rapid and specific than conventional PCR for the detection of MDV. This easy-to-perform technique will be useful for the detection of MDV and will aid in the establishment of disease control protocols.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22575575     DOI: 10.1016/j.jviromet.2012.04.014

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  Rapid, Sensitive, and Species-Specific Detection of Conventional and Recombinant Herpesvirus of Turkeys Vaccines Using Loop-Mediated Isothermal Amplification Coupled With a Lateral Flow Device Readout.

Authors:  Giulia Mescolini; Susan J Baigent; Elena Catelli; Venugopal K Nair
Journal:  Front Vet Sci       Date:  2022-06-23

2.  Application of loop-mediated isothermal amplification assay in the detection of herpesvirus of turkey (FC 126 strain) from chicken samples in Nigeria.

Authors:  A J Adedeji; P A Abdu; P D Luka; A A Owoade; T M Joannis
Journal:  Vet World       Date:  2017-11-26

Review 3.  Loop-Mediated Isothermal Amplification (LAMP) as a Promising Point-of-Care Diagnostic Strategy in Avian Virus Research.

Authors:  Faiz Padzil; Abdul Razak Mariatulqabtiah; Wen Siang Tan; Kok Lian Ho; Nurulfiza Mat Isa; Han Yih Lau; Jalila Abu; Kuo-Pin Chuang
Journal:  Animals (Basel)       Date:  2021-12-30       Impact factor: 2.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.