Literature DB >> 22574546

Inter-site validations of the Pixel-Wise method for cardiac T2* analysis in transfusion-dependent Thai thalassemia patients.

Pairash Saiviroonporn1, Vip Viprakasit, Adisak Maneesai, Noppadol Siritanaratkul, Bunchoo Pongtanakul, John C Wood, Rungroj Krittayaphong.   

Abstract

OBJECTIVE: To compare inter-site observer variability of the Pixel- Wise (PW) method for cardiac T2* analysis in thalassemia patients using the mono-exponential with a constant fitting (offset) model and to compare the cross-model variability of the offset model to the mono-exponential (typical) model. MATERIAL AND
METHOD: Eighty-eight cardiac T2* measurements were performed on 72 Thalassemia major patients. Both bright- and black-blood techniques were acquired and analyzed at both the reference (REF) and local (LOC) sites using the PW method by defined region of interest on the whole (at the REF site) and partial (at the LOC site) septum. The offset model was analyzed at the reference site while both the offset and typical models were performed at the local site. The inter-site variability of the T2* values were analyzed by independent observers blinded to the results.
RESULTS: The T2* values from the REF-offset, LOC-offset and LOC-typical methods were statistically comparable on both scanning techniques. The inter-site variations of the offset model were about 5.2% and 4.4% on the bright- and black-blood techniques, respectively, which was about 1.7% higher than from the intra-site, but was still in a reasonable range compared to the conventional method of around 5.4%. The cross-model comparisons presented with 0.4 ms of bias and variation of about 6.9% and 4.7%, respectively, which is about 1.4% higher than from the intra-site.
CONCLUSION: The observer variability on the PW method using the offset or typical model provided equivalent coefficient of variation on both scanning techniques, which was also comparable to the previous reports. The inter-site variability of the offset and cross models was also in a reasonable range, being less than 2% higher than the intra-site with bias of about 0.4 ms.

Entities:  

Mesh:

Year:  2012        PMID: 22574546

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  2 in total

1.  Long-Term Effectiveness, Safety, and Tolerability of Twice-Daily Dosing with Deferasirox in Children with Transfusion-Dependent Thalassemias Unresponsive to Standard Once-Daily Dosing.

Authors:  Jassada Buaboonnam; Chayamon Takpradit; Vip Viprakasit; Nattee Narkbunnam; Nassawee Vathana; Kamon Phuakpet; Kleebsabai Sanpakit; Bunchoo Pongtanakul
Journal:  Mediterr J Hematol Infect Dis       Date:  2021-11-01       Impact factor: 2.576

2.  Improved R2* liver iron concentration assessment using a novel fuzzy c-mean clustering scheme.

Authors:  Pairash Saiviroonporn; Vip Viprakasit; Rungroj Krittayaphong
Journal:  BMC Med Imaging       Date:  2015-11-03       Impact factor: 1.930

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.