INTRODUCTION: Intercostal catheters (ICC) are the standard management of chest trauma, but are associated with complications in up to 30%. The aim of this study was to evaluate errors in technique during ICC insertion to characterize the potential benefit of improved training programmes.
METHODS: Prospective audit of all ICC in trauma patients at a level 1 trauma centre for over 12 months. Exclusions were pigtail catheters and ICC inserted during thoracic surgery. Errors were identified from patient examination and chest imaging; they were defined as insertional, positional, incorrect size (<28 French) and lack of antibiotic prophylaxis. Ongoing complications unrelated to an error in technique, for example blocked tube, were not analysed.
RESULTS: Fifty-seven patients received a total of 94 ICC during the study period. Patients were predominantly male (77%), mean age of 40 ± 20 years, mean injury severity score 27 ± 13, mean abbreviated injury scale chest 3.8 ± 0.72. 86% were blunt trauma and 14% penetrating chest injuries. Thirty-six errors in technique occurred in 33 ICC insertions (38%). The most common errors were absence of prophylactic antibiotics (13%), ICC too far out (9%), kinked (6%) and wrong-sized ICC (5%). Emergency had a significantly greater frequency of errors than other specialties (67%, relative risk 2.11, P= 0.002). The majority of ICC were inserted by registrars, and registrars made a greater number of errors than fellows or consultants (relative risk 2.00, P= 0.02). DISCUSSION: This study identified a large number of preventable errors for ICC insertion in trauma patients. Standardized institutional credentialing systems may be required to ensure adequate proficiency of trainees performing this procedure.
© 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

Entities:  

Mesh:

Year:  2012        PMID: 22571625     DOI: 10.1111/j.1445-2197.2012.06093.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  7 in total

1.  Selective conservatism in the management of thoracic trauma remains appropriate in the 21st century.

Authors:  V Y Kong; G V Oosthuizen; D L Clarke
Journal:  Ann R Coll Surg Engl       Date:  2015-04       Impact factor: 1.891

2.  An audit of the complications of intercostal chest drain insertion in a high volume trauma service in South Africa.

Authors:  V Y Kong; G V Oosthuizen; B Sartorius; C Keene; D L Clarke
Journal:  Ann R Coll Surg Engl       Date:  2014-11       Impact factor: 1.891

3.  [Evaluation of the performance of a minimally invasive thoracic drainage tube in a rabbit model of hemothorax].

Authors:  Jia-Qing Zhang; Rui-Hong Ju; Kun-Tang Chen; Bao-Qin Ruan; Ting-Ting Xing
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-06-20

4.  Use of the iTClamp versus standard suturing techniques for securing chest tubes: A randomized controlled cadaver study.

Authors:  Jessica Mckee; Ian Mckee; Melanie Bouclin; Chad G Ball; Paul McBeth; Derek J Roberts; Ian Atkinson; Dennis Filips; Andrew W Kirkpatrick
Journal:  Turk J Emerg Med       Date:  2018-03-09

5.  Ensuring basic competency in chest tube insertion using a simulated scenario: an international validation study.

Authors:  Peter Hertz; Katrine Jensen; Saleh N Abudaff; Michael Strøm; Yousif Subhi; Hani Lababidi; Lars Konge
Journal:  BMJ Open Respir Res       Date:  2018-12-10

6.  Massive hemothorax from injury of an anonymous vein after intercostal chest drain placement: A case report.

Authors:  Motohiro Kikukawa; Akira Kuriyama
Journal:  Ann Med Surg (Lond)       Date:  2021-09-13

7.  Impact of simulation-based training in surgical chest tube insertion on a model of traumatic pneumothorax.

Authors:  Alexandre Léger; Aiham Ghazali; Franck Petitpas; Youcef Guéchi; Amélie Boureau-Voultoury; Denis Oriot
Journal:  Adv Simul (Lond)       Date:  2016-06-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.